User Guide

STAR N02

2

Maximum driver quantity per serial connection is limited. Using more quantity per run will cause overload from SMPS which 
damages all connected products. This will cause voltage drop and also dimmed lighting output.

CAUTION

Keep extension lead 
wires as short as possible.
Refer to below table for 
specific length.

CONNECTION GUIDE

Power Supply

AC Input

DC Output

Make sure that each run should have 50 modules at max
and should use another run in parallel to connect more

Should use thicker wires which can take larger amount of current
than the amount transmitted from the power supply unit

1st

2nd

49th

50th

1st

2nd

49th

50th

1st

2nd

49th

50th

1st

2nd

49th

50th

1st

2nd

Use recommended length for pitch between each module to achieve optimum lighting output while maintaining lowest unit 
cost. Failure or misplacing will cause dimmed spots or uneven appearance of light on the surface.

LAYOUT DENSITY 

GUIDELINES

RECOMMENDED PITCH PER DEPTH

100 mm

100 mm

120~150 mm

120 mm

90 mm

80 mm

70 mm

80 mm

RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH

80 mm

200 mm

400 mm

316 mm

Use 10% shorter length
than usual for circular arrange

CONNECTION WITH 

POWER SUPPLY

Output (W)

Model Name

Max Q’TY -  Colors*

Recommended

Extension Wire

Output (A)

Max Q’TY - White*

Maximum Length

30W

2.5A

PSCS-0030-12

5M (15FT)

VCTF1.25

AWG18

60W

5A

PSCS-0060-12

5M (15FT)

VCTF2.0

AWG14

120W

10A

PSCS-0120-12

5M (15FT)

VCTF2.0

AWG12

600W

50A

PSCS-0600-12**

15M (50FT)

VCTF5.5

AWG4

1000W

83A

PSCS-1000-12**

15M (50FT)

VCTF8.0

AWG2

EXTENSION OF POWER SUPPLY LEAD WIRES

*Maximum quantity for S-LED is based on 85% of specified capacity of power supplies for extended lifespan
**PSCS-0600-12, PSCS-1000-12 are not weather-proof
    Equip with protective box for outdoor use and the box should have ventilating holes

60pcs

40pcs

120pcs

78pcs

240pcs

155pcs

1200pcs

780pcs

2000pcs

1300pcs

DAEHANTRANS CO.,LTD  

#7-11 Songdo-Dong, Yeonsu-Gu, Incheon, Korea

Tel.  +82 32 858 0491  Fax.  +82 32 832 8421 enquiry@daehantrans.com / www.daehantrans.com

Summary of Contents for STAR N02

Page 1: ...ed Refer to CONNECTION WITH POWER SUPPLY on page 2 Do not use the product under circumstances listed below High temperature spots over 60 C 140 F Spots draw extreme moisture or dust Spots have corrosive gas or highly effectied by electromagnetic field Avoid performing installation under rain or high humidity for outdoor use Do not perform actions listed below Alter or modify Touch LED lamps with s...

Page 2: ...t on the surface LAYOUT DENSITY GUIDELINES RECOMMENDED PITCH PER DEPTH 100 mm 100 mm 120 150 mm 120 mm 90 mm 80 mm 70 mm 80 mm RECOMMENDED LAYOUT DENSITY PER CHANNEL WIDTH 80 mm 200 mm 400 mm 316 mm Use 10 shorter length than usual for circular arrange CONNECTION WITH POWER SUPPLY Output W Model Name Max Q TY Colors Recommended Extension Wire Output A Max Q TY White Maximum Length 30W 2 5A PSCS 00...

Page 3: ...4 41 1000 mm 1 DETERMINE LAYOUT Refer to LAYOUT DENSITY GUIDELINES on page 2 to determine spacing and amount of LEDs required SUPPORTS FOR OUR SIGNMATES Ask us to obtain accurate layout Stroke Width Channel Depth 2 PEEL AND STICK Using predetermined layout and LED placement from step 1 remove 3M tape on the back of modules and stick them into place Ensure modules are firmly attached on the surface...

Page 4: ...s a bad connection or reverse polarity connection between the modules that light and the modules that don t light Check this connection Beginning of a leg lights but the entire leg does not light or lights intermittently S LED is designed so if one module fails it will not cause the entire sign or leg to go out If one module does not light but all others in the leg do replace this module with a ne...

Reviews: