they would not be able to shut down the system or change the passwords.
Subscriber Admin
This affects only the GUI and allows access to the follow-
ing: Subscriber List, Display User Log, and Status Screen.
Min Recorded Length
This parameter sets the minimum record time that is to
be considered valid. It is specified in hundredths of a second (e.g. a setting of
50 means 0.5 seconds or 500 milliseconds). The default value is 75. If this value
is too high, short recordings will be discarded. If it is too low, the system will
consider disconnects as a valid recording.
Dial Tone Trim Size
This amount is trimmed off the end of any recorded mes-
sage that is terminated by dial tone. This parameter is measured in hundredths
of a second.
Detect on leading edge
Not used.
Minimum DTMF Duration
This parameter controls the sensitivity of the DTMF
(touch-tone) detectors only during recording of voice prompts and announce-
ments. The value represents the minimum time period (in hundredths of a sec-
ond) during which a tone must be valid in order to be accepted as a caller
entry. A lower value makes the SVMi more sensitive to DTMF tones. If exces-
Programming - Page 59
Summary of Contents for SVMi-4
Page 1: ...SVMi 4 SVM 400 Voice Mail Systems Technical Manual and User Guide...
Page 62: ...G SITE INFORMATION H STATUS SCREEN Programming Page 51...
Page 67: ...Programming Page 56...
Page 68: ...Programming Page 57...
Page 82: ...Block Tables All applications are built using blocks BYE BLOCK Programming Page 71...
Page 215: ...Samsung Business Communications Brookside Business Park Greengate Middleton Manchester M24 1GS...