4-1
4. ALIGNMENT AND ADJUSTMENTS
4-1-1. ERROR FUNCTION
1. WATER LEVEL SENSOR ERROR
(1) When the water level senser detects a frequency less than 15kHz or more than 30kHz for
more than 5 seconds
(2) Generates ERROR MELODY 5 times.
(3) DISPLAY: ‘1E’ 0.5 sec ON/OFF
(4) How to Clear: Press the START key to check again.
2. WATER SUPPLY ERROR
(1) When the water supply does not reach at the selected water level after 60 min has passed
since starting to supply water.
(2) Generates ERROR MELODY 5 times.
(3) DISPLAY: ‘4E’ 0.5 sec ON/OFF
(4) How to Clear: Press the START key to clear the error status and to resume the water supply function.
3. DRAIN ERROR
(1) When the water level does not fall under reset level after 15 min has passed since starting to drain.
(2) Generates ERROR MELODY 5 times.
(3) DISPLAY : ‘5E’ 0.5 sec ON/OFF
(4) How to Clear : Press the START key to clear the error status and to resume the water drain function.
4. DOOR OPEN ERROR
(1) When the door is opened during the intermittent spin and spin.
(2) Generates ERROR MELODY 5 times.
(3) DISPLAY: ‘dE’ 0.5 sec ON/OFF
(4) How to Clear : Close the door.
5. UNBALANCE ERROR
(1) In case the unbalance is sensed three times during the same spin cycle.
(2) In case the ERROR MELODY sounds five times.
(3) DISPLAY: ‘UE’ 0.5 sec ON/OFF
(4) How to Release: Open the DOOR and then close it.
4-1. ERROR MODE
Summary of Contents for SW82ASP
Page 22: ...4 3 ...
Page 23: ...4 4 Memo ...
Page 29: ...5 6 5 4 REASSEMBLY Reassembly procedures are in the reverse order of dissasembly procedures ...
Page 45: ...7 6 7 3 ASSY CASE A0086 U0061 A0282 I0039 I0040 I0040 B0073 B0072 B0012 B0044 B0070 ...
Page 48: ...8 2 Memo ...
Page 49: ...9 1 9 BLOCK DIAGRAM ...
Page 50: ...9 2 Memo ...
Page 51: ...10 1 10 WIRING DIAGRAM ...
Page 52: ...10 2 Memo ...
Page 55: ...12 1 12 SCHEMATIC DIAGRAMS This Document can not be used without Samsung s authorization ...
Page 56: ...12 2 Memo ...
Page 60: ...13 4 Memo ...