6-4
6-2-2. DRIVING UNIT FAILURE
- At the below instruction, it is the case that there is no failure on the power supply and key selection. it is
the diagnosis of any problem after POWER key and START key are selected and then any operation is
being normally performed.
(1) In case of no water supply
START/PAUSE key
is pressed after selecting a
course?
Yes
No
Is there any sound like ‘zee-’
at the W/S valve during water
supply?
Connect the terminal
firmly.
No W/S(water supply)
No
The terminal of W/S valve is
well connected?
Yes
W/S valve is electrically
continuous?
Water tap is opened?
Yes
Water supply has been cut
off?
No
Foreign materials exist on
W/S hose or valve?
Yes
Press Start/Pause key.
Open the water tap.
Turn off the water tap and
turn Power OFF.
Clean the filter by using a
brush.
Yes
Is the water level senser well
connected?
W/S valve is defective.
Replace it.
No
Do the pulsator rotate?
PCB Assy is defective.
Replace it.
Water level senser is
defective. Replace it.
No
Yes
Yes
No
Yes
Yes
No
No
Yes
Summary of Contents for SW82ASP
Page 22: ...4 3 ...
Page 23: ...4 4 Memo ...
Page 29: ...5 6 5 4 REASSEMBLY Reassembly procedures are in the reverse order of dissasembly procedures ...
Page 45: ...7 6 7 3 ASSY CASE A0086 U0061 A0282 I0039 I0040 I0040 B0073 B0072 B0012 B0044 B0070 ...
Page 48: ...8 2 Memo ...
Page 49: ...9 1 9 BLOCK DIAGRAM ...
Page 50: ...9 2 Memo ...
Page 51: ...10 1 10 WIRING DIAGRAM ...
Page 52: ...10 2 Memo ...
Page 55: ...12 1 12 SCHEMATIC DIAGRAMS This Document can not be used without Samsung s authorization ...
Page 56: ...12 2 Memo ...
Page 60: ...13 4 Memo ...