CHAPTER 4. H.323 Gateway Management
428
© SAMSUNG Electronics Co., Ltd.
How to Configure H.323 Bind
1.
setting the IP Address of the interface to be bound
This procedure should be executed first before executing the bind command.
y
Configuration Steps
−
configure terminal
−
interface
−
ip address
−
exit
y
Detailed Steps
Step
Command
Purpose
1 configure
terminal
Example)
# configure terminal
Enters global configuration mode.
2 Interface
type number
Example)
/configure# interface Ethernet 0/0
Enters interface configuration
mode to configure specific
interface.
3 ip
address
ip_address subnet_mask
Example)
/configure/interface/ethernet(0/0)# ip
address 90.90.90.90 255.255.255.0
Configures a IP Address for an
interface.
4 exit
Example)
/configure/interface/ethernet(0/0)# exit
Exits the current mode
Summary of Contents for Ubigate iBG2016
Page 1: ......
Page 16: ...INTRODUCTION XIV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 34: ......
Page 62: ...CHAPTER 4 System Logging 28 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 70: ......
Page 108: ......
Page 140: ...CHAPTER 4 RIP 104 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 156: ...CHAPTER 6 BGP 120 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 180: ...CHAPTER 8 VRRP 144 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 264: ...CHAPTER 10 QoS 228 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 272: ......
Page 298: ...CHAPTER 3 Firewall NAT 248 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 356: ...CHAPTER 5 IPSEC 306 SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 358: ......
Page 744: ...EQBD 000071 Ed 00 ...