background image

Fast Track Troubleshooting Manual

Power On Sequence: 
1. Standby Voltages: 

CN201-2, 4 (5V)

2. Power On  

probable error on CN201-2 

or 4 PS_ON )   

3. Low Voltage Supplies On 

CN201-

5,6,7,13,17

4. Back Light Supply On 

CN201 -16

5. Back Light Confirmation 

CN201-18

2

Wiring Diagram

Include Connector Numbers , References,  and

Locations. 

C
N
2
0
1

S  
I   
G.

P
I
N

S
I
G.

1

B12V

10

GND

2

A5V

11

GND

3

B12V

12

H_OUT

4

A5V

13

B13V

5

B5V

14

PWM
Dimming

6

B5V

15

B13V

7

B5V

16

B5V

8

GND

17

B13V

9

GND

18

IP_DET

UN40C6400QFXZA

LVDS
Cable

To Force Backlight  On 
without Main Board :

1. Remove Power Cord
2. Disconnect CN201
3. Plug In Power Cord 
4. Backlight  should be 

on immediately.  

Summary of Contents for UC6400

Page 1: ... Assy names as appearing in parts and any special labels items i e Plasma voltage label SMPS Speaker T CON below Bracket Main Speaker Woofer Version Parts No Short Description ALL BN44 00356B Power PCB SQ01 BN81 04353A T CON PCB CN02 BN81 04454A T CON PCB SS03 BN81 05079A T CON PCB H305 BN81 05769A T CON PCB HQ04 BN81 05769A T CON PCB SQ01 BN94 03404F Main PCB SQ01 BN94 03404J Main PCB CN02 BN94 0...

Page 2: ...ht Confirmation CN201 18 2 Wiring Diagram Include Connector Numbers References and Locations C N 2 0 1 S I G P I N S I G 1 B12V 10 GND 2 A5V 11 GND 3 B12V 12 H_OUT 4 A5V 13 B13V 5 B5V 14 PWM Dimming 6 B5V 15 B13V 7 B5V 16 B5V 8 GND 17 B13V 9 GND 18 IP_DET UN40C6400QFXZA LVDS Cable To Force Backlight On without Main Board 1 Remove Power Cord 2 Disconnect CN201 3 Plug In Power Cord 4 Backlight shoul...

Page 3: ...Remote Service Remote 2 Power off 2 Power On 3 Mute 182 Power 3 Info Factory Fast Track Troubleshooting Manual 2010 Models 1 Select an active source signal HDMI preferred Test Pattern may rely on signal source to appear 2 Access Service Mode 3 Access SVC 4 Access Test Patterns 5 Access Genoa P 6 Check Test Patterns 7 If OK suspect input Source 8 Access Napoli 9 Check Test Patterns 10 If OK and Gen...

Page 4: ...fective Main Board LVDS or T CON 2 Check Perform Firmware Upgrade for all repairs 3 Perform reset in Service Mode Plug and Play if Main board is replaced Vertical or Horizontal Lines Defective Panel likely but also T CON LVDS or Main Board Use Test Patterns in Factory Service Mode to determine error Option Type Model Tuner Region DDR Light Effect Audio AMP Ch Table Country Front Color Local Set Ex...

Reviews: