background image

E-

2

Safety Precautions

The following safety precautions must be taken when using your air conditioner.

Users of this product are cautioned not to attempt repair of this product
at their own discretion. Instead, they are requested to directly contact a
designated service center or the outlet at which the product was 
purchased.

Never spill any kind of liquid into the unit. Should this happen, unplug 
or main switch off the unit and contact an authorized service center.

Do not insert anything between the air outlet blades because the inner 
fan may be damaged and could cause injury. Keep children away from
the unit.

Do not place any obstacles in front of the unit.

Do not spray liquid of any kind into the indoor unit. Should this happen,
switch off the breaker used for your air conditioner and contact your
installation specialist.

Make sure that the unit is correctly ventilated at all times: 
Do not place clothing or other materials over it.

If the wireless remote control will not be used for a long time, remove
the batteries. (If applicable)

When using a wireless remote control, the distance should not be more
than 7 meters from the air conditioner. (If applicable)

WARNING

D

URING OPERATION

Never store or ship the air conditioner upside down or sideways to
avoid damage to the compressor.

The appliance is not intended for use by young children or infirm 
persons without supervision: Young children should be supervised to

ensure that they do not play with the appliance.

Max current is measured according to IEC standard for safety and 
current is measured according to ISO standard for energy efficiency.

R410a
“Do not vent R410a into atmosphere: R410a is a fluorinated 

greenhouse gas, covered by Kyoto Protocol, with a Global Warming 

Potential (GWP)= 1975”

O

THERS

Before throwing out the device, it is necessary to pull back the battery
cells and get rid of them safely for recycling reasons.

When you need to dispose of the unit, consult your dealer. If pipes are
removed incorrectly, refrigerant may blow out and come into contact
with your skin, causing injury. Releasing refrigerant into the atmosphere
also damages the environments.

Please recycle or dispose of the packaging material for this product in
an environmentally responsible manner.

D

ISPOSING OF THE UNIT

Risk of electric shock. 

• 

Can cause injury or death. 

• 

Disconnect all

remote electric power supplies before servicing, installing or cleaning. 

• 

This must be done by the manufacturer or its service agent or a similar

qualified person in order to avoid a hazard.

Register your product at www.samsung.com/global/register 

Summary of Contents for UH052EAMC

Page 1: ...ystem Air Conditioner Cooling and Heating E S F I P D G R DB98 27138A 2 Indoor Unit FH052EAMC Outdoor Unit UH052EAMC FH070EAM 1 C UH070EAM 1 C OWNER S MANUAL ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN ...

Page 2: ...ATION Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Max current is measured according to IEC standard for safety and current is measured according to ISO standard for ...

Page 3: ...pean countries with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse...

Page 4: ...er from yours depending on the model E 4 Indoor Unit Air flow blade up down Air flow blade right left Air filter Front grille Remote control sensor Filter sign indicator Defrosting indicator Fan indicator Auto indicator Timer indicator Operation indicator On Off button ...

Page 5: ...door unit gets dusty cooling efficiency may fall Disconnect all remote electric power supplies before cleaning So clean the heat exchanger with water when it becomes dirty However be careful when you wash the surface of the heat exchanger because it is very sharp N N N No o o ot t t te e e e ...

Page 6: ...ion button Filter Reset button Swing button On Timer button Off Timer button On Off Timer Set Cancel button Fan speed adjustment button Temperature adjustment buttons Temperature setting Fan speed Air flow direction On Timer setting Off Timer setting Battery discharge indicator E 6 To use the wireless remote controller refer to an appropriate manual ...

Page 7: ...SIGN indicator when the time to clean the air filter refer to page 13 N N N No o o ot t t te e e e Mode selection button Communication error indicator On Timer setting Off Timer setting Test indicator Timer Set Cancel button Test button Temperature adjustment buttons Removing frost indicator Operating mode Centralized controller indicator In case of installing the Centralized controller Filter Res...

Page 8: ...f button On Off indicators On Off buttons Index The operating lamp comes on even when only one air conditioner connected to the centralized controller is operating N N N No o o ot t t te e e e Front View Operating Mode Switch COOL AUTO HEAT Choose the appropriate operating mode with the Operating Mode Switch that enables the user to choose between the Cool Auto Heat mode N N N No o o ot t t te e e...

Page 9: ... button Then the wired remote controller will display the FILTER SIGN indicator when the time to clean the air filter N N N No o o ot t t te e e e Mode selection button Room number display Test indicator Indoor unit selection button Test button Filter Reset button Swing button Temperature adjustment buttons Temperature setting Fan speed Air flow direction Filter Sign indicator On Off Timer Set Can...

Page 10: ...here are two sets of inner air flow blades Just as the outer air flow blade can be adjusted vertically the inner blades can be adjusted horizontally Adjust each set of inner blades to the required position by pushing or pulling them sideways ...

Page 11: ... is high frost may form on the outdoor unit at HEAT mode If this happens The heating operation stops The defrost mode will be triggered automatically for about 10 minutes No intervention is required after about 10 minutes the air conditioner operates again normally Frost If both indoor and outdoor temperatures are high and the air conditioner is running at HEAT mode the outdoor unit s fan and comp...

Page 12: ...may condense on and drip from the surface of the indoor unit if it is used for a long periods High humidity levels The standardized temperature for heating is 7 C If the outdoor temperature drops to 0 C or below the heating capacity can be reduced depending on the temperature condition If the cooling operation is used at over 32 C indoor temperature it does not cool at its full capacity Mode Indoo...

Page 13: ...ashing them with a detergent and warm water below 40 C After washing allow them to dry thoroughly in an area protected from sunlight 3 Insert the air filters to the front grille 4 Close the front grille by pushing both sides and center N N N No o o ot t t te e e e If you have not used the air conditioner for a long period of time set the fan going for three or four hours to dry the inside of the a...

Page 14: ... the correct operating mode has been selected The room temperature may be too low or too high Dust may be blocking the air filter guard refer to page 13 for cleaning instructions Check that there is no obstacle in front of the outdoor unit The air conditioner does not operate with the remote controller Wireless Remote Controller Wireless Remote Controller No beep is heard when you press On Off on ...

Page 15: ...t of air FAN A device for creating a current of air or a breeze ASSY CONTROL BOX Full name assemble control box A restraining device of air condition measure or limit MOTOR Something such as a machine or an engine that produces or imparts motion ASSY EVAP ASSY COND Full name assemble evaporator assemble condenser Heat exchanger A device used to transfer heat from a fluid on one side of a barrier t...

Page 16: ...0 10 min www samsung com nl BRAZIL 0800 124 421 www samsung com br NORWAY 815 56 480 www samsung com no CHILE 800 726 7864 SAMSUNG www samsung com cl POLAND 0 801 801 881 022 607 93 33 www samsung com pl COSTA RICA 0 800 507 7267 www samsung com latin PORTUGAL 80 8 200 128 www samsung com pt ECUADOR 1 800 10 7267 www samsung com latin SLOVAKIA 0800 SAMSUNG 726 7864 www samsung com sk EL SALVADOR 8...

Reviews: