Setting the Sleep Timer
MODE TURBO OFF
The Sleep Timer can be used when you are cooling or heating your
room to switch the air conditioner off automatically after a period of
six hours.
N
N
N
N
o
o
o
o
tt
tt
e
e
e
e
If you wish to switch the unit off at a specific time, refer
to page 16.
1
Make sure that you have selected either the or the mode.
2
Press the button .
Result:
◆
The indoor unit beeps.
◆
The indication is displayed.
◆
The air conditioner will be controlled as indicated in the
illustrations below.
Cooling
The temperature is increased
by 1°C every hour.
When it has been increased
by 2°C (after two hours), the
temperature is maintained for
four hours.
Heating
The temperature is decreased
by 1°C every hour.
When it has been decreased
by 2°C (after two hours), the
temperature is maintained for
four hours.
2¡C
1¡C
Set
TEMP.
Start
time
Stop
time
1hr 2hr
6hr
-1¡C
-2¡C
Start
time
Stop
time
1hr 2hr
6hr
Set
TEMP.