-7
EN
NOTE:
Used dust bag can be sealed by remov-
ing the film from the paper and sticking
the latter over the suction opening.
TROUBLESHOOTING
FOR CLOTH FILTER BAG
MAINTENANCE OR REPLACEMENT OF THE FILTERS
PROBLEM
CAUSE
REMEDY
Motor does not start.
No power supply.
Check cable, plug and socket.
Suction force is gradually
Filter, nozzle, suction hose or
Remove the object.
decreasing.
tube is blocked.
Cord does not rewind fully.
Check that the cord is
Pull the cord out 2~3 m. & push
not twisted or wound unevenly.
down the Cord rewind button.
After using, if the cloth filter bag is full of dust, clean the cloth filter bag and use it again.
1) INLET-FILTER.
• Open the dust cover.
• After detaching the filter, wash it lightly with water, dry
it in the shade, then insert it in its original position.
• Close the dust cover.
2) OUTLET-FILTER.
• Open the dust cover, then pull the grille-filter
forward.
• Remove and replace the eshausted outlet-filter.
• Push the grille filter back, then close the dust cover.
3) After removing the used dust bag, insert the
cardboard bag collar of the new dust bag into
the carrying bag, and then insert it in its origi-
nal position
4) Press the dust cover down gently until the
clamper relocks.