21
Single
Capacity
Model
Power Supply
Voltage Range
Nominal Running
Current [A]
Current [A]
Hz
Voltage
Min.
(-10%)
Max.
(+10%)
HP
kW
Cooling
Heating
MCA
MFA
8
22.4
AM080MXWANR
50/60
380~415
342
456
6.2
6.6
16.1
20
10
28.0
AM100MXWANR
50/60
380~415
342
456
8.1
8.4
16.1
20
12
33.6
AM120MXWANR
50/60
380~415
342
456
10.3
10.4
20.0
25
20
56.0
AM200MXWANR
50/60
380~415
342
456
17.3
17.4
31.8
40
30 84.0
AM300KXWANR
50/60
380~415
342
456
26.4
26.5
48.1
63.1
Module (Premium energy efficiency type)
Capacity
Model
Power Supply
Voltage Range
Nominal Running
Current [A]
Current [A]
Hz
Voltage
Min.
(-10%)
Max.
(+10%)
HP
kW
Cooling
Heating
MCA
MFA
16
44.8
AM160MXWANR2
50/60
380~415
342
456
12.4
13.2
32.2
40
18
50.4
AM180MXWANR2
50/60
380~415
342
456
14.3
15
32.2
40
22
61.6
AM220MXWANR2
50/60
380~415
342
456
18.4
18.8
36.1
40
24
67.2
AM240MXWANR2
50/60
380~415
342
456
20.6
20.8
40.0
50
26
72.8
AM260MXWANR2
50/60
380~415
342
456
20.5
21.6
48.3
63
28
78.4
AM280MXWANR2
50/60
380~415
342
456
23.5
24
47.9
63
30 84.0
AM300MXWANR2
50/60
380~415
342
456
25.4
25.8
47.9
63
32
89.6
AM320MXWANR2
50/60
380~415
342
456
27.6
27.8
51.8
63
34
95.2
AM340MXWANR2
50/60
380~415
342
456
28.7
29.2
56.1
63
36 100.8 AM360MXWANR2
50/60
380~415
342
456
29.7
30.6
64.0
75
38 106.4 AM380MXWANR2
50/60
380~415
342
456
31.6
32.4
64.0
75
40 112.0
AM400MXWANR2
50/60
380~415
342
456
34.6
34.6
63.6
75
42 117.6
AM420MXWANR2
50/60
380~415
342
456
35.7
36.2
67.9
75
44 123.2
AM440MXWANR2
50/60
380~415
342
456
37.9
38.2
71.8
80
48 134.4 AM480MXWANR2
50/60
380~415
342
456
40.8
41.4
79.7
90
50 140.0 AM500MXWANR2
50/60
380~415
342
456
42.7
43.2
79.7
90
52 145.6
AM520MXWANR2
50/60
380~415
342
456
44.9
45.2
83.6
100
60 168.0 AM600MXWANR2
50/60
380~415
342
456
51.9
52.2
95.4
125
3. Electric Characteristics