24 _ Troubleshooting
Code Type
Code Mode
Countermeasure
Corrective Actions
Description of Photo
Drain code
Low LED
Flash
This may occur when
the drain pump is
defective.
• If the drain pump revolutions are
restrained due to freezing in the
winter season, check the method to
remove the freezing and remove as
directed.
• Check whether the revolutions of
the drain pump motor are restrained
by foreign material, and remove as
directed.
• Check the wire connectors on Main
PCB and Drain Pump ASSY. The
connector or wire may have poor
physical connection.
• Check the drain pump resistance.
Check the drain pump resistance.
(Check whether the impeller of the drain
pump motor are restrained by foreign
material .
Resistance : 13.5 ~ 16.5Ω)
This may occur due
to frozen water.
Check if there is
any alien substance
inside the draining
pump.
This may occur when
the main PCB is
defective.
Communication
code
Warm LED
Flash
The signals between
the sub and main
PBAs are not sensed.
• Check the wire connections and
terminal contacts between the sub
and main PBAs.
• Check for disconnected wires.
• Check whether the sub PBA is short-
circuited because of moisture.
• If the main PBA’s communication
circuit is faulty, replace it.
-
Incorrect wire
connections
between the sub and
main PBAs.
Water
Leakage code
High
LED
Flash
This may occur when
an alien substance is
in the DV Case.
• Since this occurs when an alien
substance is in the Draining Bellows,
for natural draining, remove the alien
substance.
• If the drain motor is defective, replace
the motor.
• Check if the water leaks from the tub
connection part.
-
This may occur due
to a defect of the
product’s internal
hose or from the part
assembly.
Switch code
(Main Relay
code)
Eco Warm
LED Flash
The Power button is
continually pressed.
A button other than
the Power button is
continually pressed.
• Check whether either the Power
switch or a tact switch is continually
pressed.
• Check whether the service PBA
holding screws are fastened too tight.
If they are fastened too tight, loosen
them a little.
• If the main PBA switching IC on/off
code has occurred, replace the main
PBA.
• The “Eco Warm LED” flashes if the
main relay connections are incorrect.
Check the connections. If there is
no flashing LED in the connections,
replace the main PBA.
Check the contact between the control
panel buttons and their corresponding tact
switch.
- There must be a gap between a control
panel button and its corresponding
micro switch.
Otherwise, an code occurs after
approx. 30 seconds has passed.