WEC8500/8050 Maintenance Manual
Version 5.1
Samsung Electronics America
page 9 of 87
CHAPTER 1.
System Management
This chapter describes the symptoms of the APC system and their solutions.
1.1 System Booting
This section describes the symptoms occurring during the system booting, their causes and
solutions.
1.1.1
Booting failure due to system overheating
While the APC system is booting, if the boot loader detects system overheat, booting is
stopped and power is automatically turned off to protect the hardware from any possible
damages.
Symptoms
During the booting, the ‘CPU overheat detected’ log indicating overheating of the central
processing unit (CPU) is displayed in the boot loader, and then the power is automatically
turned off.
WEC8500: The power is still supplied to the power module and the fan of the power
module remains operational.
WEC8050: For there is no separate power module, the fan does not operate after
power-off.
SATA link up 3.0 Gbps (SStatus 123 SControl 320)
scanning bus for devices...
Device 0: (0:0) Vendor : ATA Prod.: SanDisk SSD P4 1 Rev: SSD
Type : Hard Disk
Capacity : 15272.0 MB = 14.9 GB (31277232 x 512)
USB : USB EHCI 1.00
scanning bus for devices... 2 USB Device(s) found
Type the command 'usb start' to scan for USB storage devices.
boot partition: 2
CPU overheat detected (cpu:91, thr: 85)