CHAPTER 10. System Management
© SAMSUNG Electronics Co., Ltd.
page 485 of 689
10.4.1 Retrieving Current Alarm
All the system alarms are basically recorded into a system log. The procedure of retrieving
current alarms is as follows:
Retrieving with CLI
To retrieve current alarms, execute the command as follows:
WEC8500#
show alarm list all
1 network 2012-12-17 09:56:13 MAJ APC ge8 1301 NET Link dn
AdminStatus[up] OperStatus[down]
2 network 2012-12-17 09:56:13 MAJ APC xe1 1301 NET Link dn
AdminStatus[up] OperStatus[down]
3 network 2012-12-17 09:56:13 MAJ APC xe2 1301 NET Link dn
AdminStatus[up] OperStatus[down]
…
To selectively retrieve a group or level, execute the command as follows:
WEC8500#
show alarm list group network
1 network 2012-12-17 09:56:13 MAJ APC ge8 1301 NET Link dn
AdminStatus[up] OperStatus[down]
WEC8500#
show alarm history level major
1 network 2012-12-17 09:56:13 MAJ APC ge8 1301 NET Link dn
AdminStatus[up] OperStatus[down]
Retrieving with Web UI
To retrieve the list of current alarms, in the menu bar of
<WEC Main window>
, select
<Monitor>
and then select the
<Active Alarm>
menu in the sub-menus.
Figure 275. Current alarm