Washer Connector Checks
CN2
1 AC Pwr (L) (Blu)
3 Valves (N), Lock Sw (Blk)
(N) w/ door locked
RY1 Power Relay
1 (Wht) (N)
2 (Blu)
CN8 (Display Connector)
1 T Comm Port (Blu)
2 R Comm Port (Wht)
3 Reset Signal (Yel)
4 Ground (Org)
5 +5 vdc (Pnk)
6 +15 vdc (Red)
7 NC
8 Water level
Water Temperature Thermistor Check
Test 1
Test 2
Connector CN 3 Pin 1(white) and CN3 Pin 2(black)
Operating voltage at Room temperature
Operating Resistance at Room
Temperature (Power off) Dis-
connect CN7
4.2VDC (5VDC May indicate a connector
issue)
50-57kΩ
Door Switch Check
Test 1
Test 2
Connector CN5 Pin 6 (white) and RY2 Pin 2 (blue)
NA
Operating Resistance with
power off
40-57Ω door closed.
Water Level Sensor Check
Test 1
Test 2
Voltage: Connector CN 3 Pin 4 (pink) and CN3 Pin 2
(Orange) And Connector CN 3 Pin 3 (Violet) and
CN3 Pin 2 (Orange)
Resistance: Connector CN 3 Pin 4 (Pink) and CN3
Pin 3 (Violet)
Operating voltage at no water in the
drum-
Operating Resistance (Power
off)
2.5VDC
Pin 4 (Pink) and Pin 3 (Violet)
22- 24Ω
Hall Sensor Check
Test 1
Test 2
Connector CN8 Pin 4 (grey) and Pin 2 (Red) or Pin 4
(grey) and Pin 3 (blue)
Manually spin the drum to see the volt-
age change, Power On
N/A
0Vdc or 3.75Vdc
Motor Check
Test 1
Test 2
Connector CN1 Pin 1 (Blue), Pin 2 (White) and Pin
3 (Red)
Power Off 11.5Ω across Pins 1-2, Pins 1
-3, & Pins 2-3
300 to 400 Vac when running.
A/C Power Check
Test 1
Test 2
Connector CN 2 Pin 1 (blue) L and RY1, pin2 (blue)
N
Power On 120VAC
N/A
CN1
1 Motor Pwr U Phase (Blu)
2 Motor Pwr V Phase (Wht)
3 Motor Pwr W Phase (Red
RY2 Washer Heater Relay
1 (Blu) (L1)
2 (Red)
CN8
(Hall Sensor)
1 +5 vdc (Pnk)
2 Sensor Signal (Red)
3 Sensor Signal (Blu)
4 Ground (Org)
CN3
1 Main Valve (Blu)
2 Hot Valve (Red)
3 Bleach Valve (Pnk)
4 Drain Pump (Gry)
6 Door Lock (Wht)
Summary of Contents for WF241ANW