4. Alignment and Troubleshooting
4.1.4. Periodic Defective Image
If an image defects appears at regular intervals on the printed-paper, it is due to a faulty or damaged roller. Refer to the table
below and check the condition of the appropriate roller.
Roller
Period (mm)
Phenomenon
Defective part
1
Pressure Roller
62.8 mm
Background
2
Heat Roller
63.7 mm
Black spot and image ghost
Fuser Unit
3
Charging Roller
26.7 mm
Black Spot and line and periodic band
4
OPC Drum
62.9 mm
White and Black Spots
5
Developing Roller
33.7 mm
White spot, Horizontal black band
6
Supply Roller
78.2 mm
Periodic Band by little difference of density
Toner Cartridge
7
Transfer Roller
39.3 mm
Ghost, Damaged image by abnormal
transfer
Transfer roller
4-7