Installation
9
Reader Mechanical Installation
The MP9311 is designed for installation within an enclosure. The housing is
provided with four M4 clearance through-holes for module mounting. The reader
dimensions are shown in Figure 8.
Caution
Prior to mounting the reader in an enclosure, you must evaluate the operating conditions
and resulting thermal profile. When operated at maximum RF power and input supply
voltage, the MP9311 can dissipate as much as 11W of power. As a result, any enclosure
design must dissipate the generated thermal energy and maintain the internal reader
temperature below +85 degrees C. Mounting the bottom surface of the reader in direct
contact with a metal plate will provide the most efficient method of dissipating heat.
Figure 8–MP9311 Enclosure Dimensions
3.32
in
(84.3
mm)
3.74
in
(95.0
mm)
0.57 in (14.5 mm)
(without cooling fins)
or
0.67 in (17.0 mm)
(with cooling fins)
2.74 in (69.6 mm)
2.32 in (58.9 mm)
M4 Clearance
R0.20 Max Screw Head Size