If  you  have  a  Vomax  microwave  bale  moisture 
sensor,  an  arm  is  provided  that  can  be  used  to 

mount the barcode scanner to the Vomax stand at 

an appropriate distance. A mounting plate for the 
PLC box is also provided so that the Bale Scanner 

PLC box can be mounted to the receiver stand of 
the  Vomax.  The  scanner  cable  provided  is  long 

enough  to  mount  the  barcode  scanner  on  either 

side of the stand.  
 

 

 
Run  the  scanner  cable  from  the  scanner 

PLC  box  to  the  barcode  scanner.  Plug 
the  cable  into  the  barcode  scanner.  The 

scanner cable should be pre-wired to the 

wiring  blocks  in  the  PLC  box. 
Disconnecting  these  wires  may  make 

installation easier.  

The  correct  wiring  is  given  on  the 
barcode  scanner  wiring  diagram  at  the 

back  of  this  guide.  The  cable  should  be 
run  through  the  covered  channel  on  the 

Vomax  stand  if  the  scanner  is  mounted 

on  the  transmitter  side  of  the  Vomax. 
You  should  make  sure  that  the  colored 

wires from the cable and their respective numbered blocks match the wiring diagram in 

the back of this guide.  

 

 
 

 

Next,  run  a  CAT5  cable  from  the  ethernet  port  on 
the bale tag scanner PLC to the network switch (SJI 

part no. 21231) and plug it into an open port on the 

network  switch.  Note  that  the  cable  should  not 
exceed 300 feet in length. If this network switch is 

added, it requires 24VDC power. 

 
 

  
 

 

 
 

            

Summary of Contents for 81667

Page 1: ...bale conveyer on the side that the bale tag will be affixed Be sure that the face of the scanner is not more than 15 inches away from the bale However you need to be sure that the scanner is far enou...

Page 2: ...ode scanner The scanner cable should be pre wired to the wiring blocks in the PLC box Disconnecting these wires may make installation easier The correct wiring is given on the barcode scanner wiring d...

Page 3: ...Mount the Printer PLC box near the printer location Locate the cable that comes out of the printer PLC box and connect it to the printer It should already be wired to the terminals inside the PLC box...

Page 4: ...is necessary so that the information printed is accurate The printer should not print until after the Vomax has finished scanning the bale See the wiring diagram in this guide for more information on...

Page 5: ...Page 5 of 11 LAST UPDATE SEP 7 2018 COPYRIGHT SAMUEL JACKSON INCORPORATED 2006 ALL RIGHTS RESERVED...

Page 6: ...yo ESC MENU ENT N C N C C0 Y1 Y3 Y4 Y6 C2 Y16 Y14 Y13 Y11 N C Y0 Y2 C1 Y5 Y7 Y17 Y15 Y10 Y12 C3 G LG N C C1 X5 X7 X10 X12 C3 X22 X20 X17 X15 X0 X2 N C X4 X6 C2 X11 X13 X14 X23 X21 C4 X16 X1 X3 C0 PORT...

Page 7: ...Page 7 of 11 LAST UPDATE SEP 7 2018 COPYRIGHT SAMUEL JACKSON INCORPORATED 2006 ALL RIGHTS RESERVED...

Page 8: ...Page 8 of 11 LAST UPDATE SEP 7 2018 COPYRIGHT SAMUEL JACKSON INCORPORATED 2006 ALL RIGHTS RESERVED VS800 BARCODE SCANNER PATTERNS...

Page 9: ...of 11 LAST UPDATE SEP 7 2018 COPYRIGHT SAMUEL JACKSON INCORPORATED 2006 ALL RIGHTS RESERVED When performing a fresh setup of a DS475 Scanner scan all of the following barcodes left to right and top to...

Page 10: ...meet the particular requirements Implementation of alternative safety devices may incur additional charges No warranty of compliance with a particular standard is made in the absence of specific refe...

Page 11: ...This page intentionally blank...

Reviews: