8
Typically, the 1/2 inch crown stitcher will run for
1,000,000 cycles without additional lubrication.
However, the following procedure used after each
spool of wire will assure optimum life and
performance. Use
ISP
lubricant #CA9640.
A. Inject lube into hole, or remove and lube shafts.
B. Wipe area clean and inject a small amount of
lube into cam area.
C. Remove rotator, wipe rotator clean and lube
rotator body.
D. Apply lube to rotator ramp.
E. Wipe clean inside of rotator holder.
STITCHING HEAD
LUBRICATION:
(FIGURES 6 & 7)
Figure 6
(CTTT2605 Scene 5)
H
B
C
A
D
E
F
G
F. Inject a small amount of lube into cam area of
driver bar.
G. Inject lube into cutter operating slide.
H. Wipe driver clean, and apply a light coating of
lube.
After prolonged use (or storage) accumulations of
wire dust, dirt, or other contaminants can mix with
the stitcher lubricant. This will reduce the lubricant's
effectiveness. The following procedure is
recommended every 1,000,000 cycles.
1. Disassemble the head and clean all parts.
2. Lightly lube all sliding surfaces using
ISP
lubricant #CA9640.
3. Double check lube points A through H.