2) In case of INA ON   : 

Power ON Start 
Reset OFF Start 

3)Contorl output poerate One-shot . 
4) In case of too small time setting, 
Contact out put make error of output by responds time 

Please set minimum setting time is over 100ms or more 

 
 
 
 

 

(FLK.2) 

Flicker2 (Power Hold):In case of    Self sustain output

 

1) Timer start while INA input is ON. 
2) During   INA ON status : 

Power ON Start 
Reset OFF Start 

3) Control out self sustain operate 
4) If reached preseted   time values   

Control output change(But,Initial Start     

OUT2 control output is OFF) 

5) In case of too small time setting, 
Contact out put make error of output by responds time 

Please set minimum setting time is over 100ms or more 

 

 

(FLK.2)

 

Flicker2 (Power Hold): In case of      One-shot output

 

1) Timer start while INA input is ON. 
2) During   INA ON status    : 

Power ON Start 
Reset OFF Start 

3) Control output will One-shot operation. 
4)In case of set too small time   

Contact out put make error of output by responds time , 
So please set Min setting time more 100ms . 

 
 
 
 
 
 
 
 
 

 
 

(INT)

 

Interval(Power/Signal Reset)

 

1) ) Timer start while INA input is ON. 
2)    Reset operate while IINA is OFF. 
3)During INA ON status : 

Power ON Start 
Reset OFF Start 

4)If reached preseted   time values it become Auto Reset. 
5) Control output will ON while time processing 

 
 
 
 

 
 
 
 
 
 

 

(INT1)

 

Interval 1(Power Reset)

 

1) Timer start while INA input is ON.. 
2 During INA ON status : 

Power ON Start 
Reset OFF Start 

3) During timer process INA Input ignores. 
4) If reached preset time values it become Auto Reset.   
5) Control output will ON while time processing   

 
 
 
 

 

(OFD)

 

Signal OFF Delay(Power Reset)

 

1) During INA ON status, control output sustain ON status. 
(But, except when Power    is OFF and Reset is ON ) 
2) If reached preset time values it become Auto Reset   
 
 
 
 
 
 

 

 

 

 

a  t-

Summary of Contents for CNT-700

Page 1: ...Caution 1 Please use over M 3 5 width max 7 2m terminal wire for AC power line 2 Do not use without manufacture recommended application it may cause damage of body or broken of product 3 Please preve...

Page 2: ...change of set values Key lock display lamp Key lock operation display OUT1 2 display lamp OUT1 OUT2 operate display Counter operate display lamp Turn on when counter operate Timer operate display lam...

Page 3: ...output operate indicate Counter Operate indicate Lamp Blinking during Counter operate Timer Operate indicate Lamp Blinking during Timer operate Reset Button Reset of Counter Timer Batch Button Setting...

Page 4: ...C AC IN AC IN 100 240VAC 50 60HZ 12VDC BATCH INA INB 100mA 0V RESET INHIBIT RESET 7 6 5 4 3 2 1 9 10 11 12 13 14 8 17 18 16 19 SSR 30VDC 100mA COMMON OUT BATCH OUT T 12VDC BATCH INA INB 100mA 0V RESET...

Page 5: ...ct non voltage input NPN electric contact input connect INA INB 12VDC 0V RESET INHIBIT BATCH RESET 7 6 5 4 3 2 1 INA INB 12VDC 0V RESET INHIBIT BATCH RESET 7 6 5 4 3 2 1 AC IN AC IN 100 240VAC 50 60HZ...

Page 6: ...nal If signal of the INH terminal active the timer become stop timer Time Hold 6 INPUT TERMINAL WIREING DIAGRAM 1 INPUT NON VOLTAGE INPUT NPN 1 NO ELECTRIC CONTACT INPUT 2 ELECTRIC CONTACT INPUT SET T...

Page 7: ...INH Inhibit input during counter operation count input ignore 2 INH Inhibit input during Timer operation timer progress stop 12V SIGNAL INPUT COUNTER TIMER 0V 5 6K Sensor 12V Signal Input PNP Voltage...

Page 8: ...ode First number will blinking and become setting mode Change setting values use and key After change with wanted setting value save new values push by key 2 2 Layer Display Model Setting push one tim...

Page 9: ...ange with wanted setting value save new values push by key 2 In case of the output mode is FLK Push one time Key during operation mode First number will blinking and become t oFF set vales setting mod...

Page 10: ...Batch Counting Values increase untill Batch reset input is initiated If Batch count values reach to 999999 then go back to 0 like s circulations Batch Count Value s dose not effected for key and exte...

Page 11: ...T output timer oUt t In case of the output mode set as F N count values reach to set values it hold output ON status OUT2 output time items do not show In case of the output mode set as S T D OUT1 OUT...

Page 12: ...E COUNT SPEED OUTPUT MODE OUT2 OUT TIME OUT1OUT TIME INPUT LOGIC MIN RESET TIME DECIMAL POINT SCALE SET COUNT MEMORY KEY LOCK COUNTER TIMER SELECT PROGRAMING COUNTER Push 3 second SET key OPERATION MO...

Page 13: ...s Input logic Select input logic voltage non voltage min Reset time external RESET signal input min time interval Unit ms Decimal point Scale setting Scale setting range 0 001 99 999 Scale values K Fa...

Page 14: ...of count input of INA n setting values Preset values In case of INA is L count stop setting INB L H or unlock of count stop INB H L INA Count input stop limitation of the count input of INB INB count...

Page 15: ...A and INBis input from L to H simualtanously It sustain before count input status Incase of Encorder output A B pole connect to couter input INA INB counter mode need set to Ud C mode INA INB H L H L...

Page 16: ...d with OUT2 output R After One shot Time of OUT2 the display values will be recover to Reset Start status The Self sustain output of OUT1 will be OFF after One shot time off OUT2 The One shot output t...

Page 17: ...D ON status sustain only Preset values PRESET1 PRESET2 and Display Values is accord Please use non contact output when you seted count speed to 1kcps 10 TIME RANGE SETTING TIMER TIME RANGE FUNCTION SE...

Page 18: ...Change the setting values use by and key If push the key the cursor move to next step one by one SET UP PNT OPERATION MODE TIMER TIME RANGE UP DOWN MODE OUTPUT MODE OUTPUT TIME INPUT LOGIC INUT SIGNAL...

Page 19: ...e Timer Start 2 In case of INA ON Power ON Time Start Reset OFF Time Start 3 Control Out self sustain operate or One shot operate 4 If repeat INA input the first signal only effective OND 2 Power ON D...

Page 20: ...output by responds time Please set minimum setting time is over 100ms or more FLK 2 Flicker2 Power Hold In case of One shot output 1 Timer start while INA input is ON 2 During INA ON status Power ON S...

Page 21: ...999 0 999999 POWER INHIBIT 9999 99 0 9999 99 0 Up Display Down display 13 ONLY DISPLAY MODE OPERATION 1 Counter In case of Input mode is UP 2 Counter In case of Input mode is DOWN 3 Counter In case of...

Reviews: