41
Set the peak trim
Skew angle automatically calculated by PCU, but sometimes satellite has skew offset.
In this case, you have to set the peak to track a higher quality. Refer to below step and
Figure 4-10. This function is same with ‘TRIM’ on the ACU.
a. Change the skew angle on skew manual mode after select the desired satellite
that has skew offset.
b. Look at the Quality, then search higher quality by change of skew.
c. Click the ‘Set To Peak’, after search a higher quality.
d. Click the “Peak Save’ to save changed peak.
e. Then, SDA-390’s skew is moving to changed skew angle when select this
satellite.
Current Skew Angle
Current Signal Level(Quality)
Figure 4-10 Setting Peak Trim
NOTE: If you want reset the peak, click the ‘Peak Reset’ and click the ‘Peak Save’.