Click “Setup” button will pop up a window. You may change Name, Description, IP & Netmask of 
device. Click “Setup” to save setup. The device’s IP must be same subnet with host PC/NB enable to 
use web browser open configuration page.

 

 

 
 
Click “Goto” button will open a web page of configuration. (default ID: admin; password: admin). 

 

Summary of Contents for SC10E4M K

Page 1: ...s Modbus TCP Server and Modbus TCP Client Mode for selection It supports manual configuration via web browser and support various protocols including TCP IP HTTP DHCP ICMP and ARP These are the best s...

Page 2: ...in rail extension Weight 660 gm WARRANTY 1 year Product Panel Views Antenna Connector The connector for antenna is a standard reverse SMA jack Simply connect it to a 2 0dBi dipole antenna Standard Rub...

Page 3: ...inoperable When the power is on and the SYS LED light on use a point tip to press this button and hold it and wait for more than 25 seconds All the parameters will be reset to the factory default LED...

Page 4: ...to setup the IP Address To proceed with the parameters setup please use a web browser IE or Chrome to continue Configuration When setting up your Gateway for the first time the first thing you should...

Page 5: ...une 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Click on Find button It will scan the network and show up the IP of Gateway Etherne...

Page 6: ...ing email info santelequip com Click Setup button will pop up a window You may change Name Description IP Netmask of device Click Setup to save setup The device s IP must be same subnet with host PC N...

Page 7: ...69393 Connecting Converting Leading email info santelequip com Now you have successfully connected to the Gateway Configuration There are 4 setup pages as System Network Serial and Gateway System Setu...

Page 8: ...45 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Appearance of Wireless Ethernet setup NTP Enable Disable NTP function Set up NTP server and...

Page 9: ...ting Leading email info santelequip com Click to select the file with specified version and click Confirm button When the selected file name appears on the input column click Update button Setup is su...

Page 10: ...e 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Network setup Wireless section Type to select INFRASTRUCTURE or ACCESS POINT When selected INFRASTRUCTUR...

Page 11: ...ord and select mode DHCP or STATIC In LAPTOP PC choose same SSID to link When selected ACCESS POINT Gateway acts as an Access Point which is allowed to be connected by PC NB Smart Phone PAD It support...

Page 12: ...hts Baner Road Pune 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Password Key in selected AP log in password Encrypt Mode STATIC To...

Page 13: ...393 Connecting Converting Leading email info santelequip com Ethernet select STATIC or DHCP to assign IP address Gateway and DNS To check with MIS for right IP address Setup is successfully configured...

Page 14: ...e clearly set each parameters from Serial 1 to Serial 4 default 19200 n 8 1 Baud Rate 300 bps to 921 6K bps Parity None Even Odd Data Bits 5 6 7 8 Stop Bits 1 2 Flow Control None XON XOFF RxDelay ms 0...

Page 15: ...04 505 Deron Heights Baner Road Pune 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Four Modes are selectable Please select Gateway ty...

Page 16: ...em sends query to RTU Slave device then RTU Slave device response back to TCP Master s requirement Inside the Modbus gateway there are TCP Slave RTU Master counterparts respectively 2 TCP to ASCII Sla...

Page 17: ...e then TCP Slave device response back to RTU Master s requirement Inside the Modbus gateway there are TCP Master RTU Slave counterparts respectively Set up to 8 slaves on each port 4 ASCII to TCP Slav...

Page 18: ...tup is successfully configured Please click Save and go to other pages for configuration or click Save and Restart to run new configuration After configued all parameters click Save and Restart to reb...

Page 19: ...San Telequip P Ltd 504 505 Deron Heights Baner Road Pune 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com...