11
4.3 Report Interval Setup
#Username,0000,3,002,12*
Use this SMS message to set up the interval and frequency for
Auto Report
function.
#:
Start sign
ID:
Username
is the default ID of G-19.
Password:
Default Password is “
0000
”.
Interval Command:
You have to input “
3
” to set up the report interval.
Report Interval:
The Auto Report interval.
This parameter must be 3 digits.
The minimum
unit is 002 minutes and maximum is 120 minutes. For instance, if you setup the interval for “002”,
G-19 will send SMS message
every 2 minutes
to the indicated cellular phone.
To cancel Auto
Report function, set the interval as “000
”. The default setting of auto report is also off.
Report Frequency:
This function is to setup how many times G-19 will report to the user in Auto
Report and Parking function.
This parameter must be 2 digits.
For instance, if you setup the
report frequency for “02”, G-19 will send SMS
2 times
to the indicated cellular phone and then
stop
. If you set up this value “00” the G-19 will stop Auto Report.
*:
End sign
When the auto report of G-19 is setup successfully, G-19 will reply a SMS message:
Username setup OK. G-19 auto-report.
But if fail, G-19 will reply a SMS message:
Username setup fail.
When G-19 is in Emergency Mode, auto report is not allowed. Anyone want to start the auto
report will be replied:
Username in emergency, auto-report not allowed.
ID
Password
Interval Command
Report Int
Report Frequency