GS-818 GPS/GSM/GPRS Vehicle Tracker User Manual
30 Copyright © 2011 San Jose Technology, Inc. All Rights Reserved.
Set up Auto Report by Distance
The GPS(GPRMC) data can report to server or cellular phone automatically during a period of time or during a distance of
travel.
Use this command to set up the distance Auto Report. THE DEVICE will report only when both time interval and distance
traveled are matched. If you send the SMS command as the following example, the device will check the distance traveled
every 5 minutes (300 seconds) with previous GPS data, the device will send Auto Report if the distance exceeds 100m, or
it will not send report if the distance does not exceed 100m, it will check the distance again at the next 5 minute time
interval. The total number of reports times is 99.
Setup format:#
「
User Name
」
,
「
Password
」
,
「
Function Code
」
,
「
Intervals (sec.)
」
,
「
Total number of reports
」
,
「
Distance
Interval(m)
」
*
Example1
:
#username,0000,6,300,99,100*
Table: Auto Report by Distance Setup Format Description
Table: Auto Report by Distance Setup Response Description
SMS Text
Description
#
Start sign.
username
Default user name of the device.
If you have changed the username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
6
Mode 6 defines Auto Report setup mode.
300
Time Interval (period) of Auto Report.
99
Times (frequency) of Auto Reports that will be sent automatically.
100
Distance Interval: when the auto report function is activated, the tracker will take the
current position as the start. If this value is defined, when the tracker exceeds the distance
traveled during a time of period, the alarm report will be sent to the assigned route. The unit
of this function is meter. The minimum distance setting is 100m.
*
End sign.
Situation
Response
Setup Succeeds
[username] + Setup OK.Device Auto Report setting is updated.
Setup Fail
[username] + Auto Report setting Setup Fail!
Incorrect password
[username] + Password setup Fail!
Incorrect username or
command format
[username] + command error
Emergency Mode
[username] + Username, in emergency, setup stop.