Set up Low Power reminder
The user can send the SMS/COTA command to set up the value to alarm if the battery voltage is lower than it.
And the other LP2 can shutdown the system when the battery voltage is lower than setting.
Setup Format: #
「
MU201S2
」
,
「
Password
」
,
「
Function Mode
」
,
「
Voltage Value
」
*
Command: #MU201S2,0000,LP,3500*
#MU201S2,0000,LP2,3200*
Table41: Low Power Setup Description
Table42: Low Power Setup Response Description
SMS/ COTA Command Description
#
Start sign.
user name
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
Function Mode
Mode LP/LP2 defines the Low Power alarm setting.
Voltage Value
LP the range is 3300~4200
LP2 the range is 2500~3500
*
End sign.
Situation
Message Reply
Setup Succeeds
LP MU201S2, setup OK, LP
LP2 MU201S2, setup OK, LP2