Set up Power Saving
The power saving function helps user to saving power in order to make more service time for using.
Command: #
「
MU201S2
」
,
「
Password
」
,
「
Function Mode
」
,
「
Mode
」
,
「
On Time
」
,
「
Keep Time
」
*
#MU201S2,0000,COMBO,%1,%2(1~65535 sec),%3(1~65535 sec)*
SMS/ COTA Command Description
#
Start sign.
MU201S2
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
Function Mode
Mode “COMBO” defines the Saving Power feature.
Mode
The switch of Power saving feature.
“1” is GPS always ON.
“0” mean that will follow the setting value which after behind to close GPS.
On Time
The value will be the time (sec) will turn on the GPS before send the report.
(range: 1~65535)
Keep Time
The value will be the time (sec) will not turn off the GPS if the interval time less than
the setting.
(range: 1~65535)
*
End sign.
Table39: Power Saving Setup Format Description
Situation
Message Reply
Succeeds
MU201S2, setup OK, COMBO
Table40: Power Saving Setup Response Description
2019.09.11
新禾航電
文管中心