MU-201 GPS/GPRS Nano Tracker User Manual
Copyright © 2011 San Jose Technology, Inc. All Rights Reserved.
41
Set up Over Speed Interval
Use this command to set up the Over Speed threshold and interval. Once the Over Speed detection is enabled, the device
will start to report according speed limit, interval and times.
MU-201 provides Over Speed Detection. User can also set up detection time for misreporting.
Setup Format: #
「
username
」
,
「
Password
」
,
「
Function Mode
」
,
「
Speed Limit
」
,
「
Unit
」
,
「
Interval(Sec.)
」
,
「
Total number
of reports
」
,
「
Detection Times
」
*
Command: #username,0000,11,100,km,10,3,5*
Note1: With the above setting, the device will send Over Speed Alarm at every 10~15 second (it will be more than 10
since there is some delay in detection) when it goes over 100km/hr.
Note2: This is for “conditions setting” only, please send #username,0000,speed,on* to activate the function.
SMS/ COTA Command
Description
#
Start sign.
username
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
11
Mode 11 defines the Overspeed setup mode.
100
Speed Limit threshold. Range: 1~999.
Speed Unit per hour. There are 3 speed units for calculation:
km kilometer/hr
mi miles/hr
km
nm nautical miles/hr
10
Time Interval (period) of Over Speed Report.
3
Times (frequency) of Over Speed Reports that will be sent automatically.
5
Detection times x 3s. In this case, the device reports Over Speed if it detects continuous 5
times x 3s=15 seconds Over Speed events.
*
End sign
Table: Over Speed Interval Setup Format Description
Situation
Message Reply
Setup Succeeds
<OK>Speed limit setup, V3.793;56%
Emergency Mode
<FAIL>PANIC ON; Command not Allow!,V4.091;98%
Table: Over Speed Interval Response Description