background image

 

 

Industrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as 

following steps. 

A.

 

Open the package to check if the machine is intact and all the necessary accessories are completed.   

B.

 

Open the injection port to feed cooling water.   

Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling 

of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold 
north area, it’s better to use noncorrosive antifreeze fluid.   

C.

 

According to system conditions, please connect the water inlet and outlet pipe well.   

D.

 

Plug in power, turn on the power switch. (Do not start up without water in the water tank!)   

(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more 

bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.   

(2) After the first boot, you must immediately check whether the water pipe leaks. 

(3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the 

machine do not work. The temperature controller will automatically control the working conditions of the compressor, 

magnetic valve, fans and other parts based on the set controlling parameters.   

(4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is 

range from seconds to minutes, so do not turn off the power and again on frequently.   

E. Check the water level in the water tank.   

The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep 
the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, 

and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the 

water pipeline leakage.   

F.

 

Adjust parameters of temperature controller.   

CW-5000 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to 
“Operating status and parameters adjustment.” 

 

Summary of Contents for CW-5000AG

Page 1: ...e compact and easily movable Features It is suitable for cooling the laser tube under 150W and the temperature can be adjusted precisely You can choose different models according to local voltage and...

Page 2: ...ater circulation loop alarm causes and the work of the state table Normal Flow Indicator Flow Alarm Indicator Buzzer Output Ports Hi H2 Output Ports H1 H3 Circulating pump works properly ON OFF NOT RI...

Page 3: ...Details...

Page 4: ...he new intelligent temperature controller does not need to adjust the controlling parameters It will self adjust controlling parameters according to room temperature guaranteeing to meet cooling requi...

Page 5: ...t immediately check whether the water pipe leaks 3 Power switched on if the water temperature is below the set figure it is normal that fans and other components of the machine do not work The tempera...

Page 6: ...Power Supply AC 1P 220V 50Hz AC 1P 220V 60Hz AC 1P 110V 60Hz Current 1 4 2 1A 1 4 2 1A 3 5 5 6A Compressor Power 0 295KW 0 38KW 0 305KW 0 4HP 0 52HP 0 41HP Refrigerating Capacity 2361Btu h 2999Btu h...

Page 7: ...rature will be alternately displayed In alarming state the alarm sound could be suspended by pressing any button but the alarm display remains until the alarm condition is eliminated Thermostat parame...

Page 8: ...box Machine Dimension 550mm x 280mm x 430mm 21 6 x 11 x 17 Machine Weight 57 2ib 26kg Package Carton box Packing Size 720mm x 440mm x 620mm 28 x 17 x 25 Gross Weight 68 2ib 31kg Packing List Pictures...

Page 9: ...to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction children supervised no...

Page 10: ......

Page 11: ...rent could be up to 6 10amps sometimes The instantaneous operating current of models of AC110V power supply are possible to be up to 10 15amps 2 Please make sure there is a stable and normal voltage f...