background image

 

 

 

Maintenance 

Cooling  machine  used  in  long  term,  you  should  open  the  machine  and  clean  the  dust  in  order  to  ensure  good  heat 

dissipation. 

You can use non - corrosive antifreeze if you are in the northern cold regions. 

 

Overview

 

Specifications

   

Packing list

 

Warranty 

Specifications 

Model 

CW-5000AG   

CW-5000BG   

CW-5000DG   

Power Supply 

AC 1P 220V, 50Hz 

AC 1P 220V, 60Hz 

AC 1P 110V, 60Hz 

Current 

1.4 - 2.1A 

1.4 - 2.1A 

3.5 – 5.6A 

Compressor Power 

0.295KW 

0.38KW 

0.305KW 

0.4HP 

0.52HP 

0.41HP 

Refrigerating 

Capacity 

2361Btu / h 

2999Btu / h 

2866Btu / h 

0.692KW 

0.879KW 

0.84KW 

595Kcal / h 

756Kcal / h 

722Kcal / h 

Refrigerant   

R – 134a 

R – 134a 

R – 134a 

Refrigerant Charge 

300g 

320g 

280g 

Precision 

±

0.3

 

±

0.3

 

±

0.3

 

Tank Capacity 

6L 

6L 

6L 

Reducer 

Capillary 

Capillary 

Capillary 

Protection 

Over current protection for 

Over current protection for 

Over current protection for 

Summary of Contents for CW-5000AG

Page 1: ...e compact and easily movable Features It is suitable for cooling the laser tube under 150W and the temperature can be adjusted precisely You can choose different models according to local voltage and...

Page 2: ...ater circulation loop alarm causes and the work of the state table Normal Flow Indicator Flow Alarm Indicator Buzzer Output Ports Hi H2 Output Ports H1 H3 Circulating pump works properly ON OFF NOT RI...

Page 3: ...Details...

Page 4: ...he new intelligent temperature controller does not need to adjust the controlling parameters It will self adjust controlling parameters according to room temperature guaranteeing to meet cooling requi...

Page 5: ...t immediately check whether the water pipe leaks 3 Power switched on if the water temperature is below the set figure it is normal that fans and other components of the machine do not work The tempera...

Page 6: ...Power Supply AC 1P 220V 50Hz AC 1P 220V 60Hz AC 1P 110V 60Hz Current 1 4 2 1A 1 4 2 1A 3 5 5 6A Compressor Power 0 295KW 0 38KW 0 305KW 0 4HP 0 52HP 0 41HP Refrigerating Capacity 2361Btu h 2999Btu h...

Page 7: ...rature will be alternately displayed In alarming state the alarm sound could be suspended by pressing any button but the alarm display remains until the alarm condition is eliminated Thermostat parame...

Page 8: ...box Machine Dimension 550mm x 280mm x 430mm 21 6 x 11 x 17 Machine Weight 57 2ib 26kg Package Carton box Packing Size 720mm x 440mm x 620mm 28 x 17 x 25 Gross Weight 68 2ib 31kg Packing List Pictures...

Page 9: ...to be used by children or persons with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction children supervised no...

Page 10: ......

Page 11: ...rent could be up to 6 10amps sometimes The instantaneous operating current of models of AC110V power supply are possible to be up to 10 15amps 2 Please make sure there is a stable and normal voltage f...

Reviews: