CWFL-2000 Series
6
<4> Operation status and parameters
adjustment
The new T506 intelligent temperature controller does not need to adjust the
controlling parameters under normal circumstance. It will self-adjust
controlling parameters according to room temperature for meeting equipment
cooling requirements.
The new T506H intelligent temperature controller is selected constant
temperature control mode as factory setting with water temperature at 25
℃
.
User can adjust it as needed.
T506 and T506H controllers are of same functions and structure except
default setting.
1. Temperature control panel introduction
(1). Indicators of temperature controller working status:
COMP
ON, compressor working
SV
ON, solenoid valve working
Heating
ON, heating rod working
INT Ctrl
ON, controller working in intelligent control mode
CT Ctrl
ON, controller working in constant temperature control mode
PARAM Set ON, controller working in parameters setting mode
ALM OUT
ON, alarm output status
Room Temp ON, displaying room temperature
ST DLA
ON, starting up delay status
(2). Press
key to show the room temperature, 6 seconds later default
display restored. (Meanwhile, Room Temp light is on, displaying room
temperature.)
(3).
keys are for modifying parameters values and
keys
are for switching parameter items.
Summary of Contents for CWFL-2000
Page 1: ...CWFL 2000 DUAL TEMPERATURE AND ONE PUMP INDUSTRIAL CHILLER USER MANUAL...
Page 13: ...CWFL 2000 Series 13 changing CWFL 2000...
Page 14: ...CWFL 2000 Series 14 15 16 17 18 22 23 24...
Page 15: ...CWFL 2000 Series 15 1 2 10 3 50Hz 60Hz 4 NORMAL NORMAL 5 50cm 30cm 6 7 8...
Page 16: ...CWFL 2000 Series 16...
Page 17: ...CWFL 2000 Series 17 1 2 3 4 1 2 3 4 5 6 CWFL 2000 18...
Page 22: ...CWFL 2000 Series 22 CWFL 2000 1 2 2 H1 H2 H1 H3 E6 E6 E6 E1 E2 E3 E4 E5 5A 300V...