background image

No. 1.1 

 

CWUL-05/10/20 

Ultraviolet Laser Exclusive 

Chiller 

 

User Manual

  

 

 

Summary of Contents for CWUL-05

Page 1: ...No 1 1 CWUL 05 10 20 Ultraviolet Laser Exclusive Chiller User Manual...

Page 2: ...2 Catalog 1 Cautions 3 2 Contour and parts induction 4 3 Installation 5 4 Operation and parameters adjustment 6 5 Alarm and output ports 10 6 Technical parameters 11 7 Water pump performance curve 14...

Page 3: ...odel according to actual circumstance 4 In order to protect the water pump it is strictly forbidden to run the chiller without water in water tank The new machine will empty all water in water tank be...

Page 4: ...ook and Components WATER INJECTION PORT COOLING WATER OUTLET COOLING WATER INLET AIR OUTLET DRAIN WATER LEVEL GAUGE ALARM OUTPUT TERMINAL POWER SOCKET WITH FUSE WITH FUSE POWER SWITCH TEMPERATURE CONT...

Page 5: ...of machine not works if water temperature lower than set water after started the machine The temperature controller will automatically control the working status of compressor magnetic valve and fan e...

Page 6: ...lve working Heating ON heating rod working INT Ctrl ON controller working in intelligent control mode CT Ctrl ON controller working in constant temperature control mode PARAM Set ON controller working...

Page 7: ...r will alarm the alarm code display E2 6 F5 Ultralow water temperature alarm 1 20 15 0 When water temperature low to F0 F4 the chiller will alarm the alarm code display E3 7 F6 Ultrahigh ambient tempe...

Page 8: ...ccording to ambient temperature changes The temperature difference is controlled by F1 6 Advanced parameters adjustment cases 1 Case 1 26 8 cooling UV laser settings Chiller under constant temperature...

Page 9: ...rature display without saving the modified parameters Order Code Content Case 1 Set value Case 2 Set value Case 3 Set value T 506B Temperature controller default setting 1 F0 Temperature setting 26 8...

Page 10: ...ss than 300V Display Condition Alarm code Buzzer OUT H1 H2 OUT H1 H3 Circulating pump works properly DISCONNECTION BREAKOVER Ultrahigh room temp E1 Sounds BREAKOVER DISCONNECTION Ultrahigh water temp...

Page 11: ...er temperature alarm Pump power 50 W Inlet and outlet External 10mm barbed connector Max lift 12M Max flow 13L min Tank capacity 6 L N W 23Kgs G W 26Kgs Dimension 58X29X47 cm L X W X H Package dimensi...

Page 12: ...pillary Protection Overcurrent protection for compressor flow alarm over temperature alarm Pump power 50 W 100 W Max lift 12M 25M Max flow 13L min 16L min Tank capacity 6 L N W 24Kgs G W 27Kgs Dimensi...

Page 13: ...Capillary Protection Overcurrent protection for compressor flow alarm over temperature alarm Pump power 50 W 100 W Max lift 12M 25M Max flow 13L min 16L min Tank capacity 6 L N W 26Kgs G W 29Kgs Dime...

Page 14: ...CWUL 05 10 20 Series 14 7 Refrigeration performance curve Performance curve of chiller under ambient temperature 20 30 and 40...

Page 15: ...are blocked or a pipe bending deformation Check water circulation pipe Ultrahigh water temperature alarm controller displays E2 Blocked dust gauze bad thermolysis Unpick and wash the dust gauze regula...