CWUL-05/10/20 Series 

   

5

Advanced settings adjustment 

1

  Press and hold the

” button while press SET button for 5 seconds until 00 

displayed  in  upper  window  and  PAS  in  lower  window.  Then  press  keys  to 
select the password (default setting is 8), and then press the SET button, if 
the password is correct, F0 displays, entering into setting status, means the 

temperature controller is under parameter setting status. If the password is 
incorrect,  it  returns  to  temperature  display.  To  avoid  operation  mistake, 
passwords could change by equipment user or equipment keeper. 

2

Enter  setting  status,  press 

buttons  to  modify  parameter  content 

follow  by  recycle,then  press  “

”buttons  to  modify  the  parameter 

values. Press confirm button RST at any time to exit parameters setting with 
saving  modified  parameters  and  return  to  temperature  display,  then  chiller 
runs under the new parameters. If there is no any action within 20 seconds, 
the  controller  will  automatically  exit  parameters  setting  without  saving  the 
modified  parameters  (under  parameters  setting  status,  system  running  in 
original  parameters).  Under  parameters  setting  status,  SET  key  does  not 
work. 

Note: 

1. During parameters setting status, system runs under original parameters.   

2.Under  constant  temperature  control  mode,  the  water  temperature  is 

controlled by parameter F0. 

        3. Under intelligent control mode, the water temperature will be automatically 

adjusted according   

to  ambient  temperature  changes.  The  temperature  difference  is  controlled 
by F1. 

6.

 

Advanced parameters adjustment cases

 

1

Case 1

26.8 

 cooling UV laser settings   

Chiller  under  constant  temperature  control  mode,  press  SET  button  will 

display  setting  water  temperature  value

F0

,then  press 

or 

buttons  to  modify  setting  temperature  value,  set  the  temperature  to 

26.8 

,press  RST  button  save  parameter  and  exist  then  back  to  the 

temperature  display  (If  there  is  no  any  action  within  20  seconds,  the 
controller  will  automatically  exit  parameters  setting  return  to  temperature 
display without saving the modified parameters) 

2

Case 2

  16

 cooling UV laser settings   

Chiller  under  constant  temperature  control  mode,  press  SET  button  will 

display  setting  water  temperature  value

F0

,then  press 

or 

buttons  to  modify  setting  temperature  value,  set  the  temperature  to 

16.0 

,press  RST  button  save  parameter  and  exist  then  back  to  the 

temperature  display  (If  there  is  no  any  action  within  20  seconds,  the 
controller  will  automatically  exit  parameters  setting  return  to  temperature 
display without saving the modified parameters) 

3

Case 3

Change alarm temperature of water temperature ,water temperature 

higher 5 

 than set value will alarm ,lower 10 

 than set value will alarm.   

              Press  and  hold 

button  while  press  SET  button  lasts  5  seconds  the 

temperature  controller  will  display  0,  then  press

button  modifies  0  to 

8(default  setting  password),and  then  press  SET  button  will  enter  setting 
content code display turns to F0 if password corrects (Will restore to actual 

water  temperature  if  password  incorrect).  Press 

or 

button 

Summary of Contents for CWUL-05

Page 1: ...No 1 1 CWUL 05 10 20 Ultraviolet Laser Exclusive Chiller User Manual...

Page 2: ...2 Catalog 1 Cautions 3 2 Contour and parts induction 4 3 Installation 5 4 Operation and parameters adjustment 6 5 Alarm and output ports 10 6 Technical parameters 11 7 Water pump performance curve 14...

Page 3: ...odel according to actual circumstance 4 In order to protect the water pump it is strictly forbidden to run the chiller without water in water tank The new machine will empty all water in water tank be...

Page 4: ...ook and Components WATER INJECTION PORT COOLING WATER OUTLET COOLING WATER INLET AIR OUTLET DRAIN WATER LEVEL GAUGE ALARM OUTPUT TERMINAL POWER SOCKET WITH FUSE WITH FUSE POWER SWITCH TEMPERATURE CONT...

Page 5: ...of machine not works if water temperature lower than set water after started the machine The temperature controller will automatically control the working status of compressor magnetic valve and fan e...

Page 6: ...lve working Heating ON heating rod working INT Ctrl ON controller working in intelligent control mode CT Ctrl ON controller working in constant temperature control mode PARAM Set ON controller working...

Page 7: ...r will alarm the alarm code display E2 6 F5 Ultralow water temperature alarm 1 20 15 0 When water temperature low to F0 F4 the chiller will alarm the alarm code display E3 7 F6 Ultrahigh ambient tempe...

Page 8: ...ccording to ambient temperature changes The temperature difference is controlled by F1 6 Advanced parameters adjustment cases 1 Case 1 26 8 cooling UV laser settings Chiller under constant temperature...

Page 9: ...rature display without saving the modified parameters Order Code Content Case 1 Set value Case 2 Set value Case 3 Set value T 506B Temperature controller default setting 1 F0 Temperature setting 26 8...

Page 10: ...ss than 300V Display Condition Alarm code Buzzer OUT H1 H2 OUT H1 H3 Circulating pump works properly DISCONNECTION BREAKOVER Ultrahigh room temp E1 Sounds BREAKOVER DISCONNECTION Ultrahigh water temp...

Page 11: ...er temperature alarm Pump power 50 W Inlet and outlet External 10mm barbed connector Max lift 12M Max flow 13L min Tank capacity 6 L N W 23Kgs G W 26Kgs Dimension 58X29X47 cm L X W X H Package dimensi...

Page 12: ...pillary Protection Overcurrent protection for compressor flow alarm over temperature alarm Pump power 50 W 100 W Max lift 12M 25M Max flow 13L min 16L min Tank capacity 6 L N W 24Kgs G W 27Kgs Dimensi...

Page 13: ...Capillary Protection Overcurrent protection for compressor flow alarm over temperature alarm Pump power 50 W 100 W Max lift 12M 25M Max flow 13L min 16L min Tank capacity 6 L N W 26Kgs G W 29Kgs Dime...

Page 14: ...CWUL 05 10 20 Series 14 7 Refrigeration performance curve Performance curve of chiller under ambient temperature 20 30 and 40...

Page 15: ...are blocked or a pipe bending deformation Check water circulation pipe Ultrahigh water temperature alarm controller displays E2 Blocked dust gauze bad thermolysis Unpick and wash the dust gauze regula...