Introduction

Qualified Persons   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Read this Instruction Sheet    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Retain this Instruction Sheet .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  2
Proper Application    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Operating Considerations  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Special Warranty Provisions  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Warranty Qualifications    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Safety Information

Understanding Safety-Alert Messages  .  .  .  .  .  .  .  .  .  .  . 4
Following Safety Instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Replacement Instructions and Labels    .  .  .  .  .  .  .  .  .  .  . 4

Safety Precautions

   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

Shipping and Handling

Inspection   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Packing   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

Installation

Before Starting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7 
Mounting the Panel-Mounted GridMaster Controller 

Inside the Enclosure  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8 

Making the Control Power, Data, and GPS 

Connections   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

Final Setup and Checkout    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .14

Appendix

General Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .15
Module Pinouts   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .15

Summary of Contents for GridMaster

Page 1: ...tion 2 Operating Considerations 2 Special Warranty Provisions 3 Warranty Qualifications 3 Safety Information Understanding Safety Alert Messages 4 Following Safety Instructions 4 Replacement Instructi...

Page 2: ...n Sheet This instruction sheet is a permanent part of your GridMaster Microgrid Control System Designate a location where you can easily retrieve and refer to this publication Proper Application WARNI...

Page 3: ...anty does not apply to any equipment that has been disassembled repaired or altered by anyone other than the seller This limited warranty is granted only to the immediate purchaser or if the equipment...

Page 4: ...tant procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If you do not understand any portion of this instruction sh...

Page 5: ...rsons See the Qualified Persons section on page 2 2 SAFETY PROCEDURES Always follow safe operating procedures and rules 3 PERSONAL PROTECTIVE EQUIPMENT Always use suitable protective equipment such as...

Page 6: ...ier immediately 2 Ask for a carrier inspection 3 Note the condition of shipment on all copies of the delivery receipt 4 File a claim with the carrier If concealed damage is discovered 1 Notify the del...

Page 7: ...with the same safety precautions that would be applied when accessing other high voltage lines and equipment Follow all locally approved safety procedures when working on or around the controller Bef...

Page 8: ...quiring removal of the controller or surrounding equipment The GridMaster controller should be mounted in an appropriate NEMA enclosure or equivalent for protection from weather dust and unintentional...

Page 9: ...nector on the controller STEP 2 Connect a solid copper Ethernet cable to the Ethernet 0 port on the controller The other end of the cable may be connected to either a radio a network switch or directl...

Page 10: ...th of wire is 1000 meters 3281 feet There is no required order for use of the screw terminals When using stranded wire S C recommends coating the stranded ends with tin solder before insertion into th...

Page 11: ...n for the opposite state Digital outputs sink capacity 10 mA On board 5 Vdc current 50 mA The screw terminals can accept 14 to 24 AWG wire When using stranded wire S C recommends coating the stranded...

Page 12: ...s with tin solder before insertion into the screw terminals Pinouts are shown in the Module Pinouts section starting on page 15 Analog IO Port Module This module provides input and output ports to mea...

Page 13: ...stalled on the door of the enclosure This switch will be pre installed on the enclosure door When the door is opened the contact inside the reed switch is made and the microgrid controller will detect...

Page 14: ...are trained and or harnessed so movement of the panel will not loosen the connection STEP 3 Turn on the control power to the GridMaster controller by toggling the ON switch in the upper right hand co...

Page 15: ...X 4 Ground 5 Ground 6 Data RX 7 Power 8 Power RS 485 Connector Module General Specifications Control Voltage 9 to 39 Vdc Operating Temperature 25 C to 70 C 13 F to 158 F Operating Humidity 95 non cond...

Page 16: ...16 S C Instruction Sheet 1025 510 Appendix CAN Port Module Analog IO Port Module Digital Input Output Module Vdc Vdc Vdc Vdc...