Check Points
Error
Code
Error Contents
Error Detection Condition &
Diagnostic
Connector
No. or
Maintenance
Monitor No.
Connector
Colour
Judgment & Repair Methods
E140
Compressor rotation error was
detected
㩷
㩷
㩷
㩷
<Check Items>
㩷
㩷
㩷
㩷
- Check for HP control PC board
connector connection
㩷
㩷
- Confirm connector connections
㩷
- Trouble in air absorption due to
foreign object blocking air path
through evaporator
㩷
㩷
- Remove foreign object from
evaporator if any
㩷
- Check dust being stuck on HP
connector filter
㩷
㩷
- Remove foreign object from filter if
any
㩷
- Bends or blockings and freeze
on HP connection pipes
㩷
㩷
-Correct piping and remove bends
and blockings
㩷
- Stopper valve is closed
㩷
㩷
- Open stopper valve
㩷
- Air exists in water pipe
㩷
㩷
- Remove air
㩷
- Water circulation pump
malfunction
㩷
㩷
- Conduct operation check on water
circulation pump
㩷
- Compressor wiring error
㩷
㩷
- confirm connection of wire terminals
to compressor is in the right order
㩷
- Power cutoff occurred
㩷
㩷
- Check Power supply cable wiring
layout
㩷
- Power supply voltage error
㩷
㩷
- Confirm power supply voltage
(240+/-14V)
㩷
- Error in connection on power
supply terminal block
㩷
㩷
- Confirm wire connection on terminal
block.
㩷
INV Motor Operation
Detection Error
- PC board malfunction
㩷
㩷
- PCB replacement required if same
error occurs again after re-run of heat
pump
E141
Overload Detected in compressor
operation control
㩷
㩷
㩷
㩷
<Check Items>
㩷
㩷
㩷
㩷
- Check for HP control PC board
connector connection
㩷
㩷
- Confirm connector connections
㩷
- Compressor wiring error
㩷
㩷
- confirm connection of wire terminals
to compressor is in the right order
㩷
- Error in connection on power
supply terminal block
㩷
㩷
- Confirm wire connection on terminal
block.
㩷
- Check dust being stuck on HP
connector filter
㩷
㩷
- Remove foreign object from filter if
any
㩷
- Bends or blockings and freeze
on HP connection pipes
㩷
㩷
-Correct piping and remove bends
and blockings
㩷
- Check if stopper valve is open
㩷
㩷
- Open stopper valve
㩷
- Air exists in water pipe
㩷
㩷
- Remove air
㩷
- Water circulation pump
malfunction
㩷
㩷
- Conduct operation check on water
circulation pump
㩷
- Power cutoff occurred
㩷
㩷
- Check Power supply cable wiring
layout
㩷
- Power supply voltage error
㩷
㩷
- Confirm power supply voltage
(240+/-14V)
㩷
INV Overload Detection
Error
- PC board malfunction
㩷
㩷
- PCB replacement required if same
error occurs again after re-run of heat
pump