Sanden Heat Pump – Installation Manual
Page 5 of 32
Installation location
The tank unit should be located as close as possible to the most frequently used hot
water outlet such as a kitchen or bathroom. It may be located either outside or
inside. The heat pump unit must be located outside and as close as practicable to
the tank, but not further than 15 metres distance from it.
Ensure sufficient clearance around the heat pump unit to allow air to circulate and
provide adequate space for service maintenance of the unit (Figure 3).
Install the heat pump unit in an area which allows sufficient ventilation. Poor
ventilation may cause the unit to short cycle and this could increase the power
consumption by more than 10%.
Do not install the heat pump unit in a confined space.
If the heat pump unit is installed facing a wall, exhaust air may stain the wall.
There must be adequate space between top of heat pump & anything above it to
allow for access to top controls for servicing.
Figure 3: Restrictions on where the heat pump unit can be installed (overhead view)
Flat wall installation
Corner installation
150mm or more
150mm or more
150mm or more
150mm or
more
150mm or
more
※1
※1
※1
350mm or more in case of the height of wall is less than 1200mm.
600mm or more in case of the height of wall is more than 1200mm.