Appendix A: Post-Installation Procedures
82005-IM-K
Sandel SN3500 Installation Manual
Page 7-4
7.1.3
Page 3: COMPASS SYSTEM
The Compass System page configures the gyro and fluxgate (if applicable) to the
SN3500.
Configuration Field
Options
Comment
HEADING NONE
429
429H
XYZ
XYZ-
MID CONT
KG102
Selects the gyro input to the SN3500.
VALID
NONE
HIGH
LOW
Not shown if 429 or 429H is selected for
heading.
FLXGATE NONE
KMT112
COLLINS
HONEYWELL
STEC 6446
Selects model of fluxgate input when
slaving is performed internally.
QUAD
0.0°
90.0°
180.0°
270.0°
Set automatically when fluxgate is
selected.
PEAK
0
-
7
Set automatically when fluxgate is
selected