17
CORRECT CHANGE ONLY CONTROL (protected menu)
CORRECT CHANGE RULE (MDB only)
IF IN CCOC CON = 0 VMC manages automatically the changer setting
CCU correct change value
If (changer is able to change back (CCU value + Maximum Price))correct change message
is not showed otherwise correct change message will be show.
On this mode the VMC automatically accepts only coins and /or bill that can be returned to
the customer.
ACC (Unconditional acceptance value) is automatically managed equal to the Maximum
price.
IF IN CCOC CON=1 VMC manage the changer setting according to CONFY setting
Correct change led is set according to C2 (Low change equation ) and C3 (minimum coins
Tube level ) setting.
If correct change is OFF VMC accept coins set in CONFY - C06 and C07 and bill set on
CONFY- C4.
If correct change is ON VMC accept coins set in CONFY - C08 and C09 and bill set on
CONFY- C5.
ACC (Unconditional acceptance value) is automatically managed equal to the Maximum
price
If the ENTER button is activated at the "CCOC" prompt the VMC will show the actual
overpay status “"CON X", where X is 0 (overpay not allowed) or 1 (overpay allowed), use
up or down button to select the other submenu available (“CCU”, “ACC” and “CONFY”), or
press enter button to change X value. The submenu are:
CCU
If you press enter at the “CCU” prompt, the display shows the actual value, you
can change it using up or down button.
ACC
If you press enter at the “ACC” prompt, the display shows the actual value, you
can change it using up or down button
CONFY (Submenu, are used by VMC only if CCOC-CON = 1) if you press enter at the
“CONFY” prompt, the display shows“C1”, using up or down button you can
choose the other submenu (“C1”-“C12”), which have this function: