Ambient Temperature Display 

To turn the ambient temperature display on or off:  with the controller on, press and hold the Time 

button and press the I/O button.  (This feature is disabled in firmware revision 4.01). 

 

  

Front Door 

If the front door is opened (HFD6 and 7 only), the controller turns off only the lights. The display 

reads "

OPEn

". After closing the front door, the lights turn on and the display reverts to internal 

ambient temperature. 

 

  

Heater Temperature Adjustment   

Push the 

I/O 

button to turn the unit off.  The lights and heaters turn off. 

With controller power off, hold down the 

TIME

 button then press and hold the 

I/O

 button until the 

display comes on.  The display will show the firmware revision. 

Push either of the two buttons corresponding to the shelf that you wish to change the temperature.  

Both lights on either side of the buttons will begin blinking. 

Push and hold the button on the left to decrease the temperature (shown on the display). 
Push and hold the button on the right to increase the temperature (shown on the display). 
Repeat the procedure using the buttons that correspond to each of the six shelves (for HFD6 & 7), or 

four shelves (HFDM). 

Once the temperatures are adjusted for each of the separate zones, push the 

I/O

 button to lock in 

the new temperature settings and to turn the HFD back on (the lights in the HFD will come on). 

 

  

Error Codes  

E30  Internal ambient thermistor open circuit 
E60  Upper left shelf thermistor open circuit (except HFDM)  E63  Upper right shelf thermistor open circuit 
E61  Middle left shelf thermistor open circuit (except HFDM) E64  Middle right shelf thermistor open circuit 
E62  Lower left shelf thermistor open circuit  

 

     E65 Lower right shelf thermistor open circuit 

E90  Unable to read USB drive (check vendo.cfg for file format error) 
 
E70  Upper left shelf not heating (except HFDM)   

E73 

Upper right shelf not heating 

E71  Middle left shelf not heating (except HFDM)   

E74 

Middle right shelf not heating 

E72  Lower left shelf not heating   

 

 

E75 

Lower right shelf not heating 

 

- For E60 to E65 (heater thermistor error) and E70 to E75 (heater failing to reach set temperature 
after several hours), the indicator for that heater blinks red. Pushing the button next to the blinking 
red indicator displays the error code for about 5 seconds.   

- Clear all errors by powering off the HFD, correcting the problem, and turning the HFD on again. 

 

 

  

Programming using USB drive 

The file name must be vendo.cfg and be saved on the root directory of the USB drive.  The file may 

be edited using Notepad.  

 

  

Temperature and Timer Programming Format and Download 

SV01   

 

Must be SV01 

001h   

 

This is configuration 001, h for standard HFD (n for HFDM, c for HFDC, etc.) 

UL:235,2:00,0:30 

U

pper 

L

eft shelf, set to 235ºF, left timer 2 hours, right timer 30 minutes 

ML:235,2:00,2:00 

 

Shelf temperatures may be set between 100 and 265ºF 

LL:220,1:00,2:00 

 

Setting a shelf temperature to 000 turns off that shelf 

UR:235,2:00,1:00 

 

Shelf temperature must be 3 digits, always in ºF 

MR:235,2:00,2:00 

 

Each timer may be set between 0:30 and 4:00 

LR:220,1:00,2:00 
CF:1   

 

1 displays ºF, 0 displays ºC 

Summary of Contents for HFD000006

Page 1: ...l MODELS HFD000006 8 HFDC00002 thru 5 HFDM00002 3 HFDH00001 thru 3 HFDHC0001 thru 14 Table of Contents Commitment to Safety 2 Safety Warnings 3 Parts 4 Operation 12 Troubleshooting 16 Controller Conne...

Page 2: ...ecommend a similar commitment to safety by every servicing organization Only properly trained personnel should have access to the interior of the machine This will minimize the potential hazards that...

Page 3: ...lectric shock or fire do not use volatile or flammable products in or near the HFD When moving the HFD turn the HFD off unplug and allow the unit to cool To prevent glass breakage and injury do not pu...

Page 4: ...76 Shelf Assembly Middle Right 10 1207453 Shelf Assembly Upper Right 11 1158685 Gasket A 12 1158696 Gasket B 13 1159513 Lamp Socket 14 1159525 Xenon Heating Lamp 15 1255614 Power Cord Plug 16 1257854...

Page 5: ...603 1 Frame Gasket Horizontal 2x 4 1185603 2 Frame Gasket Vertical 2x 5 1187405 Damper one each side 6 1202273 Extension Spring one each side 7 1199716 Rack Top Middle Shelf not shown 4x 8 1213748 Rac...

Page 6: ...ers Side glass with decal Used on HFD HFDC and HFDM Left 1274406 LT CSP Right 1274406 RT CSP 1177435 Front Gasket not shown 1207488 Bottom Shelf Assembly 1177198 Front Door 1203125 Caution Hot Label 1...

Page 7: ...age for Controller Connections for electrical component part numbers 1279466 Shelf Assembly 1279466 1 Shelf Assembly 1177198 Front Door 1279273 Shelf Guard 1279447 Shelf Rack 1201293 1 Controller 1279...

Page 8: ...3 4 Vertical Frame Gasket 1158696 2 Side Gasket 1259326 Power cord 1257854 Breaker 1253573 1 Rt Front Door w center handle HFDHC0009 10 For HFDHC0001 through HFDHC0008 use kit p n 1262114 to get a mat...

Page 9: ...CSP Left Side Glass with Decal 6 1274406 RT CSP Right Side Glass with Decal 7 1277863 Rack Top Middle Shelf not shown 2x 8 1277294 Rack Bottom Shelf not shown 2x 9 1268759 Shelf Guard 2x 10 1268627 S...

Page 10: ...ller to Door Switch HFD000008 only 8 1203069 CSP Slide Door HFDC00005 Front Door Damper Parts same each side except as indicated Item Part Description 1 1259989 Left Door Assembly w Center Handle 2 12...

Page 11: ...rt Description 1 1180812 Fan HFDC00005 only 2 1276654 Fan Harness HFDC5 only 3 1164041 Thermistor 4 1206526 Thermistor Extension 5 1185869 Dial Thermometer 6 1273469 LED High Temperature 7 1222415 Swi...

Page 12: ...to 30 minutes again Once the timer is activated the LED next to the shelf timer button stops blinking and stays on The display then reverts to HFD internal air temperature While a timer is on pressing...

Page 13: ...Upper left shelf thermistor open circuit except HFDM E63 Upper right shelf thermistor open circuit E61 Middle left shelf thermistor open circuit except HFDM E64 Middle right shelf thermistor open circ...

Page 14: ...01h UL 235 2 00 1 00 ML 235 2 00 2 00 LL 220 1 00 2 00 UR 235 1 00 1 00 MR 235 2 00 2 00 LR 220 2 00 1 00 CF 1 DA 1 DS 1 SV01 001n UL 000 2 00 2 00 ML 000 2 00 2 00 LL 245 2 00 2 00 UR 245 2 00 2 00 M...

Page 15: ...R 245 2 00 2 00 MR 245 2 00 2 00 LR 245 2 00 2 00 CF 1 DA 1 DS 0 HFDC Left Side Right Side Heater Setpoint F Left Timer Right Timer Heater Setpoint F Left Timer Right Timer 240 2 00 2 00 240 2 00 2 00...

Page 16: ...oes not reach 150 F One or more heater plates not reaching temperature An error E70 to E75 may be displayed on controller HFD HFDC and HFDM need 30 minutes to reach temperature HFDH and HFDHC needs at...

Page 17: ...Fan with Switch 1187843 Rocker Switch 1180812 Fan 2x 7x 1127484 Fuse 3 15 amp slow blow 250V 5x20 mm Newer model controllers do not have replaceable heater fuses Left Right as viewed from the control...

Page 18: ...SANDENVENDO AMERICA INC 1213686M ECN 58848 18 Older controller appearance and schematic...

Page 19: ...mote On Off 1159408 Light Harness Top 2x 1163898 Harness Controller HFD 3 4 5 1202145 Harness Controller HFDC only 1187878 Harness Fan with Switch 1180812 Fan 2x 1161921 Breaker Fuses F1 Upper Left Sh...

Reviews: