Instructions for the installer, maintenance
technician and final user
Page 16 of 54
© SandenVendo Europe SpA
Fig. 2.1
C
A
B
2.3 Technical features
Bottle and Can
C36-XS
C47-S
C48-M
C4X-L
Dimensions
Height (A)
1830 mm
1830 mm
1830 mm
1830 mm
Width (B)
650 mm
750 mm
850 mm
1015 mm
Depth (C)
800 mm
955 mm
955 mm
955 mm
Weight
280 Kg
300 Kg
340 Kg
375 Kg
Power supply
Nominal voltage
220 / 240 V
Nominal frequency
50 / 60 Hz
Max. power consumption
650 W
700 W
700 W
700 W
Fuses
F1-
T10A ■ F2-T1A
Refrigeration unit
Compressor
8.77 cm³
8.77 cm³
8.77 cm³
8.77 cm³
Expansion
Direct with capillary tube
Cooling system
Forced air with evaporator 2 fans
Refrigerant type
* R290
GWP
3
3
3
3
Refrigerant charge
0.066kg
0.078kg
0.078kg
0.078kg
T e CO2
0,000198
0,000234
0,000234
0,000234
Adjustable temperature range
+1°C up to +25°C
Climate class
ST (+18°C up tp + 38°C)
Noise level
< 70 dB
Electronic control
MDB
Payment system protocol
MDB / Executive
*Equipment contains flammable gases.
The flammable gases are contained in hermetically sealed equipment conform at
IEC 60335-2-89 norms
WARNING:
Keep clear of obstruction all ventilation openings in
the appliance enclosure or in the structure for building-in.
WARNING:
Do not damage the refrigerant circuit.
WARNING:
In order to reduce flammability hazards the
installation of this appliance must only be carried out by a suitably
qualified person.
WARNING:
Don’t use electrical and mechanical device, unless
they are of the type recommended by the manufacturer.