Test Mode Display:
Allows you to verify that all of the characters on the display illuminate.
1.
At “Test Mode” press Button 4.
2.
Press Button 2 or 3 to scroll until display reads “Test Mode - Display.”
3.
Press Button 4.
4.
All of the characters on the display should illuminate.
5.
Press Button 4 to exit.
Selection Switch Testing:
Allows you to test the selection switches.
1.
At “Test Mode” press Button 4.
2.
Press Button 2 or 3 to scroll to “Test Mode Switches”.
3.
Press Button 4
4.
Press desired selection switch to be tested.
5.
To exit press Button 1 and hold for 3 seconds
Test Mode - Relays:
Allows you to test the compressor, evaporator fan, lights and heater.
•
At “Test Mode” press (2)
•
Press (1) until display reads “Test Mode - Relays”
•
Press (2)
•
To advance through sub-modes, press (1)
•
To test compressor, press (2) at “Compressor” prompt
•
Press Button 4 at “Light” prompt to test lighting system.
•
Press Button 4 at “Fan” prompt to test evaporator fan.
•
To test optional heater, press (2) at “Heater” prompt
•
To exit sub-modes, press (3)
Cash Data:
Allows you to retrieve historical information regarding the money accepted by the vendor. To
clear the individual selection cash data, you must have the “MIS Auto Reset” in the
“Configuration” mode turned to ON.
•
Press (2) when the display reads “Cash Data”
•
The non-resettable historical data is displayed
•
To display resettable individual selections, press (1)
•
To reset historical data, make sure the “MIS Auto Reset” is turned ON in the
configuration mode.
•
To exit mode, press (3)
V21 12.3
Programming HVV | P4-4