Cleansing and maintenance
of the ozone generator
Humidity and dust contamination in the inlet air
cause ozone output to be reduced substantially.
With this in mind, the ozone generator has
been designed for easy maintenance and
cleansing.
With continuous operation, it is recommended
that the ozone generator be examined for
contamination about once every 3 to 6 weeks.
Before cleansing the ozonizer, please set the
ozone output to zero, but keep it running for a
few minutes. This will cause any residual ozone
to be removed from the ozone generator.
Opening and cleansing of the ozone generator
⇒ Turn off the ozonizer (
I/O
button).
⇒ Allow the ozone generator
(5)
to cool down.
⇒ Disconnect the power cable from the mains
socket.
⇒ Remove the plug from the power supply
connector
(7)
.
⇒ Disconnect the tubing for inlet air and ozone.
⇒ Remove the screws
(4)
holding the ozone
generator cover
(5)
in place using the
supplied hex-tip tool.
⇒ Remove the ozone generator cover
(5)
.
⇒ Wipe the ozone generator’s ceramic plates
with a sponge (if necessary, by using
household scouring agent). Please make
sure to remove any deposits from the
connection nipples as well.
⇒ Allow to dry.
Reassembly to resume operation
after cleansing
⇒ Reattach the ozone generator cover
(5)
,
taking care that the insulating o-ring is
seated firmly in its groove.
⇒ Tighten the hex-tip screws
(4)
crosswise
until they are hand-tight.
⇒ Reattach the tubing for inlet air and ozone.
⇒ Reconnect the 24 volts plug into the power
supply socket
(7)
.
⇒ Reinsert the wall plug into the mains socket.
⇒ Turn on the ozonizer (
I/O
button).
Display cleansing
⇒ To clean the display,
use a microfiber cloth only.
⇒ Cleansing only with hand gloves,
eye protection, and proper clothes.
Caution with acid residues.
⇒ Dry immediately.