background image

17

•  Do not insert any object through the air output grille.
•  Cleaning and user maintenance shall not be made by children without supervision.
•  Before carrying out any maintenance work, or during long periods without use make sure 

that the purifi er has been disconnected from the mains.

•  The purifi er is designed only for indoor use. It is recommended to close the windows when 

in use.

•  Use the appliance as described in this instruction and as air purifi er.
•  Do not use the air purifi er in an area of fl ammable, combustible or explosive air.
•  Do not use the appliance in areas with toxic vapors, fl ammable powders or oxygen tanks.

4.  TECHNICAL CHARACTERISTICS

Model

Power

(W)

Maximum 

current

(A)

Electrical power 

supply

RPM

Airfl ow 

to clean 

fi lter

(m

3

/h)

Airfl ow 
to dirty 

fi lter

(m

3

/h)

Surface 

to be 

treated*

(m

2

)

Sound 

level

(dB)

PAP 850 H14

180

1,2

1F /230V, 50-60Hz 2900

850

600

60 - 80

50

PAP 650 CA H14

178

1,1

1F /230V, 50-60Hz 2900

700

500

50 - 67

49

PAP 650 VOC H14

178

1,1

1F /230V, 50-60Hz 2900

700

500

50 - 67

49

* Application in commercial premises and of

Þ

 ces with 3 meters of free ceiling height.

The technical characteristics are common to vertical and horizontal versions.

5.  HANDLING

•  The PAP purifi ers are supplied packed in a single cardboard box.
•  When unit received, unpack and make sure the packaging is intact; any defect may indicate 

damage to the unit. If any defect or damage is found, please do not install neither try to 
repair the unit, please contact the dealer in case.

•  The unit should be handled carefully.
•  Manipulate the unit by hand. If using a forklift, place the unit on a pallet. Do not manipulate 

the purifi er directly with the blades of the forklift.

6.  RECEPTION

Inside the box you will fi nd the following material:

•  Purifi er PAP 850 or PAP 650.
•  Cable with plug (2m. Long).
•  Instructions manual.
•  Numbered Certifi cate of absolute fi lter H14, which confi rms that the fi lter has shown its 

effi ciency of ≥99.995% in a laboratory test.

•  Sticker that certifi es that your premises have an adequate air quality.
•  Wrench  necessary  to  remove  the  panel  that  gives  access  to  the  fi lters  (for  start-up  and 

maintenance).

Summary of Contents for AIRPUR PAP 650V

Page 1: ...PAP 650 PAP 650V PAP 850 PAP 850V ES EN ...

Page 2: ...L CHARACTERISTICS 17 5 HANDLING 17 6 RECEPTION 17 7 DIMENSIONS 18 8 LOCATION 18 8 1 Purifier components 20 8 2 Use conditions 20 8 3 Commissioning 21 9 AIRFLOW ADJUSTMENT 21 9 1 PAP 850 H14 model 22 9 2 PAP 650 CA H14 and PAP 650 VOC H14 models 23 10 PREVENTIVE MAINTENANCE 24 10 1 Filters 24 10 2 Fans 25 ...

Page 3: ...ply with safety standards and any possible modifications to the pro duct The EC seal and statement of conformity serve as proof of the product s compliance with applicable European Community standards 3 SAFETY INSTRUCTIONS CAUTION Read carefully the safety warnings before starting to install the product in order to reduce the risk of fire electric shock or dagames Check that the power supply corre...

Page 4: ...4 178 1 1 1F 230V 50 60Hz 2900 700 500 50 67 49 Application in commercial premises and ofÞces with 3 meters of free ceiling height The technical characteristics are common to vertical and horizontal versions 5 HANDLING The PAP purifiers are supplied packed in a single cardboard box When unit received unpack and make sure the packaging is intact any defect may indicate damage to the unit If any def...

Page 5: ... appliance on ramps or surfaces with significant unevenness Two of the wheels have a safety brake Once the unit is placed in its final location activate the wheel brake To do this apply pressure with your foot on the safety brake Fig 1 When choosing the location take into account the following recommendations In the case of horizontal versions facilitate the entrance of air to the intake grid to t...

Page 6: ...on of the diffuser Fig 4 PAP purifiers are equipped with various filters including an absolute filter with an efficien cy of 99 99 To ensure the proper functioning of the appliance and to enjoy good air quality for a longer time it is essential to locate the appliance in a dry and clean environment 10 cm Fig 1 Fig 2 Fig 3 Fig 4 ...

Page 7: ...over of filter access Air outlet diffuser Inlet protection guard Rear wheels Front wheels with safety brake 8 2 USE CONDITIONS PAP units are indicated for air purification in commercial and clean sanitary environ ments Do not use the unit in dusty environments as this would cause quickly satura tion of the filters or damage the motor Respect the following environmental conditions Model PAP 850 H14...

Page 8: ...t out of its bag and return it to its position Fig 3 Perform the same operation with activated carbon and VOC filters in case your unit incorporates them Close the cover again fixing it with the corresponding screws CA VOC filter according to version F7 pre filter H14 filter A A AIR AIR Fig 1 Fig 2 Fig 3 Once the filters have been disbursed the unit is ready to be started up Connect the power cabl...

Page 9: ...10 4 6 7 9 10 3 5 5 7 8 9 10 3 5 6 7 8 9 10 2 5 4 5 6 7 8 9 10 Premises with medium occupation offices meeting rooms commercial establishments classrooms Height m Surface m2 20 25 30 35 40 55 70 5 7 8 9 10 4 5 6 7 8 9 10 4 5 7 7 8 9 3 5 5 6 7 7 8 10 3 5 5 6 7 7 9 2 5 4 5 5 6 7 8 10 Premises from the previous point with high occupancy cafeterias restaurants waiting rooms Height m Surface m2 20 25 3...

Page 10: ...50 60 70 80 5 8 10 4 5 8 9 4 7 8 10 3 5 6 8 9 10 3 6 7 8 9 10 2 5 5 6 7 8 9 10 Premises with medium occupation offices meeting rooms commercial establishments classrooms Height m Surface m2 20 25 30 35 40 55 5 8 9 10 4 5 7 8 9 10 4 6 8 8 9 10 3 5 6 7 8 8 9 3 6 6 7 8 8 10 2 5 5 6 6 7 8 9 Premises from the previous point with high occupancy cafeterias restaurants waiting rooms Height m Surface m2 20...

Page 11: ...le gloves during the ma nipulation of the filter Minimize contact time with filters Once removed deposit the filters in hermetic plastic bags and contact our technical service which you will find at www solerpalau es or contact a professional with a Waste Manager qualification to treat the filters according to the procedures established in your community Cleaning and replacing of filters F7 pre fil...

Page 12: ...for the retention of gases and odors VOC CA To remove this filter just pull it up CA VOC filter according to version F7 pre filter H14 filter A A AIR AIR Fig 1 Fig 2 Fig 3 When installing the new filters make sure that the air direction of the filter label matches with the airflow in the unit Once the filters have been maintained replaced follow the previous steps in reverse order before commissio...

Page 13: ...S P SISTEMAS DE VENTILACIÓN S L U C Llevant 4 Polígono Industrial Llevant 08150 Parets del Vallès Barcelona España Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com Ref 9023092300 ...