This instruction manual contains important 
information and must be read carefully by 
competent  persons  prior  to  any  handling, 
transport,  inspection  or  installation  of  this 
product. Every care has been taken in the 
preparation  of  the  instructions 

and 

information; however, it is the responsibility 
of  the  installer  to  ensure  the  system 
complies  with  relevant  national  and 
international regulations, especially safety. 
The manufacturer, Soler & Palau Sistemas 
de 

Ventilación 

S.L.U. 

accepts 

no 

responsibility  for  breakages,  accidents  or 
any  inconvenience  caused  by  failure  to 
comply  with  the  instructions  contained  in 
this manual. 
The  fan  units  referred  to  in  this  manual 
have  been  manufactured  in  accordance 
with 

rigorous 

quality 

control 

and 

International standard ISO 9001. Once the 
product has been installed, this manual to 
be retained by the end user. 
 
Transport and manipulation. 
The  packaging  used  for  this  fan  unit  has 
been 

designed 

to 

support 

normal 

transporting conditions. The  fan unit must 
always  be  transported  in  its  original 
packaging as not doing so could deform or 
damage  the  product.  The  fan  unit  must 
always  be  transported  in  its  original 
packaging. Do not accept delivery if the fan 
is  not  in  its  original  packaging  or  shows 
clear signs of having been damaged. 
The product should be stored in a dry place 
in  its  original  packaging,  protected  from 
dust  and  dirt  until  it  is  installed  in  its  final 
location. 
Do not place heavy weights on the packed 
product and avoid impact damage. 
Any lifting equipment must be safe and of 
suitable  capacity  for  weight  and  size. 
Special  attention  may  be  required  to 
ensure fan assembly does not distort or tilt 
as weight distribution may vary. Never lift a 
product by pulling it by the wires or terminal 
casing.  Likewise,  no  pressure  should  be 

applied  on  the  propeller,  turbine  or  safety 
grid while manipulating the product. 
 
Storage 
Storage must be  in  a safe, flat, controlled 
environment 

to 

prevent 

damage, 

especially 

from 

water, 

sand, 

dust, 

moisture, 

corrosion, 

temperature. 

Recommend that duct connections (inflow 
and 

outflow) 

are 

closed 

to 

avoid 

dust/debris entering the equipment.  
These data may also apply to an installed 
fan,  which  is  not  put  into  operation  for 
extended period. 
 

Important information for the safety 
of installers and users. 
Installation  must  be  carried  out  by 
qualified 

persons 

acting 

in 

accordance 

with 

all 

safety 

precautions  applicable  and  as 
required  by  law,  regulations  and 
standards in the country applicable. 
All  fan  units  are  designed  and 
manufactured  in  accordance  with 
EC 

Directive. 

Safety 

guard 

accessories are available from S&P 
if 

required 

due 

to 

specific 

installation. 
Working  ambient  temperature  for 
fan  unit  equipment  should  not  be 
exceeded typically this will be within 
-20°C  to  +40°C,  unless  stated 
otherwise. 

 

This  fan  unit  must  not  be  used  in 
explosive 

or 

corrosive 

atmospheres. 
If  the fan  unit  is  to extract  air from 
premises  where  a  boiler  or  other 
combustion  appliance  is  installed, 
make  sure  that  the  room  has 

Summary of Contents for CAB Series

Page 1: ...CAB CAB B CVB VENT VENT V...

Page 2: ......

Page 3: ...YELLOW GREEN BROWN BLUE L L N N 230V 50Hz L N N L N REB CAB CVB SLIMBOX CAB REB CVB SLIMBOX REB L L N N 230V 50Hz L N N L N REB 2 hilos est ndar 2 wires standard 2 fils standard 3 hilos mejor 3 wires...

Page 4: ...z BLACK YELLOW GREEN BROWN BLUE L L N N 230V 50Hz L N N L N REB CAB B VENT CAB B REB VENT REB L L N N 230V 50Hz L N N L N REB 2 hilos est ndar 2 wires standard 2 fils standard 3 hilos mejor 3 wires be...

Page 5: ...Fig B 1 1 2 3 4 5 6 1 1 2 3 4 5 6 1 1...

Page 6: ...39 ECA RA 45 45 39 BEHS 5 40 m3 h Dn e w ctr BEHS 5 45 BEHS 10 40 BEHS 10 45 BEHT 15 30 m3 h Dn e w ctr BEHT 15 50 EC HY 6 45 6 45 33 BEHT 15 75 ECA HY 6 45 6 45 37 BEHT 15 100 ECA HY 6 45 RA 6 45 39...

Page 7: ...la h lice o turbina ni por la reja de protecci n Almacenaje El almacenaje del producto debe realizarse en su embalaje original y en un lugar seco y protegido de la suciedad de la humedad de la corros...

Page 8: ...nstalarse como indicado en la definici n del control de la demanda central indicada en el reglamento 1253 2014 ver esquemas de las fig B dados como ejemplos Puesta en servicio Comprobar que los valore...

Page 9: ...ner la declaraci n de conformidad otro documento de la CE o copia de este manual consultar la p gina WEB www solerpalau com Requisitos de informaci n para las UVR a Marca b Identificador c CEE clima t...

Page 10: ...talled in its final location Do not place heavy weights on the packed product and avoid impact damage Any lifting equipment must be safe and of suitable capacity for weight and size Special attention...

Page 11: ...hown on nameplate Fan unit should then be levelled on any anti vibration mountings Flexible connectors must be taught to ensure no disruption to air flow especially on inlet to fan unit Make sure ther...

Page 12: ...iners and hand in the replaced units to the nearest handler of this type of waste product The fan unit is mainly made of steel copper ferrite aluminium and plastic These components should be recycling...

Page 13: ...bles lectriques la bo te de bornes l h lice ou la turbine ou encore par la grille de protection Stockage Le stockage du produit doit tre effectu dans son emballage d origine dans un lieu sec et prot...

Page 14: ...olaire ayant une ouverture entre contacts d au moins 3 mm bien dimensionn par rapport la charge et conforme aux normes en vigueurs Pour le branchement lectrique suivre les indications du sch ma de rac...

Page 15: ...les D chets lectroniques Pour toute question concernant les produits S P contacter votre distributeur Pour sa localisation ou pour obtenir la d claration de conformit de l UE d autres documents r glem...

Page 16: ...nipulation von schweren Produkten sollten angemessene Hubelemente verwendet werden um zu vermeiden dass Personen oder das Produkt selbst zu Schaden kommen Das Hubsystem sollte sicher und dem Gewicht u...

Page 17: ...ssen gem ss der europ ischen Verordnung 1253 2014 mit Steurerung nach rtlichem Bedarf installiert werden Zubeh r erforderlich Siehe Abb B als Beispiel Inbetriebnahme Es sollte berpr ft werden dass die...

Page 18: ...die Produkte von S P kontaktieren Sie unseren After Sell Service falls Sie sich in Spanien befinden und ihren H ndler wenn Sie sich au erhalb von Spanien befinden F r die Lokalisierung und den Erhalt...

Page 19: ...141 157 282 287 817 i 39 6 40 8 90 3 89 5 265 j 37 34 42 43 54 k 0 028 0 031 0 055 0 056 0 161 l 50 50 50 50 50 m 0 272 0 253 0 273 0 285 0 357 n 0 65 0 65 0 65 0 65 0 65 n1 Local demand Local demand...

Page 20: ...VSD f None None None g NA NA NA h 311 322 338 i 65 4 62 9 62 6 j 47 48 48 k 0 061 0 063 0 066 l 50 50 50 m 0 231 0 214 0 202 n 0 65 0 65 0 65 n1 Local demand Local demand Local demand o NA NA NA o1 2...

Page 21: ...VSD VSD VSD f None None None g NA NA NA h 259 611 698 i 89 4 242 5 153 8 j 43 56 51 k 0 051 0 12 0 137 l 50 50 50 m 0 281 0 445 0 235 n 0 65 0 65 0 65 n1 Local demand Local demand Local demand o NA N...

Page 22: ...239 239 292 292 245 280 i 59 3 59 3 60 60 56 4 57 4 j 50 50 51 51 50 51 k 0 047 0 047 0 057 0 057 0 048 0 055 l 50 50 50 50 50 50 m 0 198 0 198 0 17 0 17 0 237 0 211 n 0 65 0 65 0 65 0 65 0 65 0 65 n1...