12
Settings:
The fans are set to operate at 60%
relative humidity and with 2 minutes
run-on time.
If the humidity in the room is lower than
60%, the fan will not turn on. If it is higher,
the fan will operate until the humidity level
drops below 60%RH and then runs for
the length of time set by the timer. The
desired humidity level and time delay are
set by means of adjusters positioned on
the printed circuit board (fig. 9) and
accessible once the grille (1) has been
removed.
The humidity is set by the adjuster.
“
% Hr
”
- To reduce the humidity setting turn
anticlockwise (min.60 %)
- To increase the humidity setting turn
clockwise (max. 90 %)
The timer is set by the adjuster
“
t min.
”
- To reduce the run-on time, turn
anticlockwise (min. 2 minutes)
- To increase the run-on time, turn
clockwise (max: 20 minutes).
ATTENTION: When the fan is on
run-on time phase, you must let it
finish before a new setting.
Note:
If the fan never turns on.
- Humidity adjuster is not at its lowest
setting. Turn anticlockwise the adjuster
(do not force the adjuster) to the
minimum setting.
- The fan is fitted in an area where there
is no air flow.
- The humidity level in the room is below
60% RH
If the fan never stops:
- Humidity adjuster is not at its highest
setting. Turn clockwise the adjuster (do
not force the adjuster) to the maximum
setting.
- The humidity level in the room is above
90% RH
DECOR-100 CD and CDZ
Models provided with a PIR (passive
infra-red) detector and adjustable "run
on" timer (1 to 30 minutes).
The unit starts automatically when a
movement is detected with a maximum
distance of 2 metres (fig.8) and will
continue to operate for the set period.
The desired run-on time is selected by
means of an adjuster positioned on the
printed circuit board (fig. 7) and
accessible once the grille (1) has been
removed:
- To reduce the run-on time, turn
anticlockwise (min. 1 minute)
- To increase the run-on time, turn
clockwise (max: 30 minutes).
User instruction
This instruction is available under
http://www.solerpalau.com or contact
your National Soler & Palau contact. List
see http://www.solerpalau.com.
This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experienceand knowledge if they have
been given supervision or instruction
concerning use of the appliance in a safe
way and understand the hazards
involved. Children shall not play with the
appliance.Cleaning and user
maintenance
shall not be made by children without
supervision.
Cleaning and maintenance
The other surface of the Fan needs only a
periodical cleaning, using a cloth lightly
impregnated with a soft detergent.
S&P reserves the right to alter
specifications without notice
Summary of Contents for Decor-100 CHZ Visual
Page 1: ...Soler Palau Decor 100 CHZ Visual 5210022900...
Page 2: ...DECOR 100 DECOR 200 DECOR 300...
Page 3: ......
Page 5: ...4 Fig 2...
Page 6: ......
Page 7: ...5 Fig 4 Fig 3 L N Fig 5 L N L N...
Page 8: ...6 Fig 7 Fig 8 Fig 6 Fig 9 L N L N...
Page 12: ......
Page 18: ......
Page 24: ......
Page 30: ......
Page 36: ......
Page 42: ......
Page 47: ...39 60 Hr 90 HR DECOR 100 CD and CDZ PIR 1 30 2 fig 8 fig 7 1 1 30 8 S P...
Page 48: ......
Page 49: ...40 DECOR DECOR ISO 9001 www solerpalau com Soler Palau 1 Fig 1 1 2 3 4 5 D COR 2 Fig 2 4 Fig 1...
Page 51: ...42 90 1 8 Fig 8 2 1 6 Fig 6 60 2 60 60 60 9 Fig 9 Hr 60 90 t min 2 20...
Page 52: ...43 60 90 DECOR 100 CD CDZ 1 30 2 8 Fig 8 7 Fig 7 1 30 Soler Palau Soler Palau 8...
Page 54: ......