ENGLISH
EcoAIR DESIGN Centrifugal Extractor
Fans
The EcoAIR DESIGN extractor fan range
is manufactured to the high standards of
production and quality as laid down by
the international Quality Standard ISO
9001. All
components have
been
checked and every one of the final
products will have been individually
tested at the end of the manufacturing
process.
On receipt of the product we recommend
that you to check the following:
1- That it is the correct model.
2- That the details on the rating label are
those you require: voltage, frequency...
The installation must be carried out in
accordance with the electrical standards
in force in your country.
This appliance is not intended for use by
young children or infirm persons unless
they have been adequately supervised by
a responsible person to ensure that they
can use the appliance safely. Young
children should be supervised to ensure
that they do not play with the appliance
Installation
IMPORTANT
:
Before installing and
wiring the unit, ensure that the main
supply is disconnected.
Fig. 1:
1 : Front grille
2: Protection cover
3: Support
4 : Connection terminals
5 : Cable entry
6 : Dip switches
The ECOAIR DESIGN is suitable for wall
or ceiling mounting and can either
discharge directly to the outside or via an
individual ducting system (see Fig. 2).
Make a hole in the wall or ceiling of
diameter 105 mm.
If the unit is to be installed with individual
ducting, use a standard duct of diameter
100 mm.
Remove the front grille (1) and the
protection cover (2).
The unit can be mounted on the wall or
ceiling using the 4 rubber blocks and the
screws provided.
Ensure that there are no obstructions to
the airflow and that the impeller turns
freely.
Introduce the mains cable through the
cable entry (5) and fix it to the wall.
Connect the electrical wiring as set out
below and then mount the protection
cover and the front grille.
Electrical connection
The EcoAIR DESIGN is an extractor
designed for a single phase supply, with
voltage and frequency as indicated on
the rating plate of the unit. The units are
manufactured with double electrical
insulation (Class II) and therefore they do
not need an earth connection.
The electrical installation must include a
double pole switch with a contact
clearance of at least 3 mm.
The electrical cable must enter the
EcoAIR DESIGN through the cable entry
(5).
Once the cable has been introduced
proceed using the electrical wiring
diagram applicable to the selected
model.
Operation
The EcoAIR DESIGN is an extractor
designed to operate continuously at low
speed
and
constant
volume.
The
constant flow setting is made with dip-
switches placed on the electronic circuit
board (Fig. 1):
Summary of Contents for EcoAIR DESIGN
Page 1: ...EcoAIR DESIGN...
Page 2: ...Fig 1 6 7 P2 P3 P1 SW1 1 SW1 2 SW1 3 SW1 4 SW1 5 1 2 3 4 5...
Page 3: ...Fig 2...
Page 4: ...Fig 4 Fig 3 Fig 5 L N L N L N...
Page 5: ...Fig 7 Fig 6 Fig 8 P2 min L N L N...
Page 6: ...Fig 10 Fig 9 Fig 11 L N P2 min P3 HR L N...
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 41: ......
Page 42: ......
Page 43: ......