background image

2

INTRODUCTION:

DO NOT INSTALL, USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL 

HAS BEEN READ AND UNDERSTOOD. READ AND SAVE THESE INSTRUCTIONS 

FOR FUTURE USE. 

This document is the property of the owner of this equipment and is required for future 

maintenance. Leave this document with owner after installation or service has been 

completed.

It is the responsibility of the purchaser to assure that the installation and maintenance of this 

equipment is handled by qualified personnel experienced in such work and equipment.

We strongly suggest hood Installation should only be performed by a qualified and 

licensed mechanical contractor who is familiar with the level of involvement for proper 

installation. Ensure proper safety precautions are taken, permits are obtained, and code 

requirements are met.  

Contact your local representative should you need further information.

SHIPMENT AND RECEIVING:

Prior to shipment, all fans have been thoroughly inspected and tested.

All equipment shipped from S&P is skidded or crated to fully comply with trucking 

requirements. Inspect all shipments carefully for damage. 

THE RECEIVER MUST 

NOTE ANY DAMAGE ON THE CARRIER’S BILL OF LADING AND FILE A CLAIM 

IMMEDIATELY WITH THE FREIGHT COMPANY, IN THE CASE OF ANY DAMAGE.

 

Keep a record of all equipment received, including inspection details and date of receipt, 

because of the possibility of partial shipments.

If you receive damaged goods, contact your manufacturer’s representative for repair or 

replacement service.

HANDLING:

Handle your equipment with caution

STORAGE:

If hoods are stored for any length of time, they should be stored in a clean, dry location to 

prevent rust and corrosion. Outdoor storage is not recommended. When outdoor storage is 

necessary, they should be protected from the elements. 

Summary of Contents for JENcoFAN EO

Page 1: ...tion of fans manufactured by S P USA These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures because of the wide variety and...

Page 2: ...ts are met Contact your local representative should you need further information SHIPMENT AND RECEIVING Prior to shipment all fans have been thoroughly inspected and tested All equipment shipped from...

Page 3: ...consent of its Jacksonville Florida office The foregoing shall constitute our sole and exclusive warranty and our sole and exclusive liability and is in lieu of all other warranties whether written o...

Page 4: ...vane anemometer across the filter bank Multiply the average velocity by the cross sectional area of the duct in square feet or by the net free area of the filter bank If the airflow as measured is no...

Page 5: ...Filters in fan clogged Clean filters and replace Fire system not armed or has been activated Ensure micro switch on fire system is wired properly Arm fire system Hood Not Capturing Smoke Dirty grease...

Page 6: ...ed in accordance with standard SMACNA Low Pressure requirements Field Installed Duct Collars When ordered exhaust and supply collars are shipped loose not connected to hood and intended to be field in...

Page 7: ...greasing with a food grade high temperature silicone Clean grease extractors daily in a dishwasher or other containers with a mild detergent in warm hot water Never use harsh or abrasive cleaners on s...

Page 8: ...8 END TO END CONFIGURATION...

Page 9: ...9 BACK TO BACK CONFIGURATION...

Page 10: ...10 GREASE TROUGH AND CUP INSTALLATION...

Page 11: ...1 1 HOOD OPTIONS 1 1 BACK RETURN PLENUM...

Page 12: ...12 HOOD OPTIONS 1 2 FRONT PERFORATED SUPPLY PLENUM FPSP...

Page 13: ...13 HOOD OPTIONS 1 3 STAINLESS STEEL WALL SPLASH PANELS...

Page 14: ...14 HOOD OPTIONS 1 4...

Page 15: ...15...

Page 16: ...S P USA Ventilation Systems LLC 6393 Powers Avenue Jacksonville FL 32217 T 904 731 4711 F 904 737 8322 www solerpalau usa com...

Reviews: