background image

ENGLISH 

Thank you for placing your confidence in S&P by buying 

this product. It has been manufactured following current 

technical safety regulations in accordance with EC 

standards. Please read this instruction booklet carefully 

before installing and starting up the product. It contains 

important information on personal and user safety 

measures to be followed while installing, using and 

carrying out maintenance work on the equipment. Once 

the product has been installed, please hand in this 

booklet to the end user. Check that the appliance is in 

perfect condition while unpacking. Any fault or damage 

caused in origin is covered by the S&P guarantee.

Ensure that all the values of main supply are compatible 

with those indicated on the rating plate. 

Transport and manipulation. 

- The packaging used for this appliance has been

designed to withstand normal transport conditions.

The appliance must always be transported in its

original packaging as not doing so could deform or

damage the product.

- The product should be stored in a dry place in its

original packaging, protected from dust and dirt until it

is installed in its final location. Do not accept delivery if

the apparatus is not in its original packaging or shows

clear signs of having been manipulated in any way.

- Do not place heavy weight on the packed products

and avoid knocking or dropping it.

- When manipulating heavy products, adequate

elevating machinery should be used to avoid harming

people or damaging to the product itself.

Safety on Installation: 

- Before handling this appliance, make sure that it is

disconnected from the power supply.

- Installation must only be carried out by a qualified

professional.

- The installation must be in accordance with the

electrical standards and regulations in force in your

country.

- The electrical installation must include a double pole

switch with a contact clearance of at least 3 mm,

correctly sized and in accordance with the electrical

standards of the country of installation.

- This appliance is not intended for use by young

children or infirm persons unless they have been

adequately supervised by a responsible person to

ensure that they can use the appliance safely. Young

children should be supervised to ensure that they do

not play with the appliance.

- Once it has been commissioned, the appliance must

comply with the following Directives:

Low Voltage Directive 2006/95/CE

Electromagnetic

Compatibility Directive 

2004/108/EC.

- The installer must use heating batteries that are in

perfect condition

- When you install the battery, make sure that all

mounting parts are in place and that the structure on

which they are installed is resistant enough to support

the battery.

- The electrical heaters are designed for indoor

installation. The maximum air temperature at the

outlet must not be over than 40ºC

- Fit the battery respecting the airflow direction

indicated by the arrow located on the battery.

- Use the batteries only for heating clean air. If the

heating elements become dirty, there is a risk of fire.

We recommend installing an air filter upstream from

the heater with a minimum distance of twice diameter

between the filter and the heater.

- Do not use these batteries in explosive or corrosive

atmospheres.

- The maximum air ambient temperature around the

heater must be lower than 35ºC

- Do not install the battery in a place of the duct system

where there is a risk of condensation.

- The electrical connection should provide a device for

controlling the air flow. The heating battery has to be

operative only when it reaches the minimum flow or

an air velocity higher than 1.5 m/s.

- The electrical installation has to ensure that the

electric heater battery cannot start up if the fan is

switched off. The battery has to start up after or at the

same time as the fan.

- The electrical installation has to ensure that the fan

cannot be stopped when the electric battery is

operating. The fan has to stop after the battery has

been switched off and cooled.

- Never fit MBE-R batteries with the terminal box

downwards.

- The distance between the battery and components of

the duct system such as bends, dampers or other

types of accessories must be at least twice the

diameter of the MBE-R type battery.

- In the event of insulating the heating battery use only

non-flammable insulation (M0) and place it keeping

the rating plate visible and the connection box cover

easily accessible.

- The distance between the sheet metal casing of the

battery and inflammable materials must be more than

150mm. If these distances cannot be maintained,

provide insulation around the battery.

- If the batteries are fitted to the terminal part of the

installation, a grille or other type of protection must be

fitted to prevent any direct contact with the heater

battery.

- Please follow the connection diagrams for the

electrical connection.

Starting up 

Before starting up the appliance, make sure that: 

- The appliance is well secured and the electrical

connections have been carried out correctly.

- The electrical safety devices are duly connected

- There are no loose materials or fitting remains in the

area of the heater battery.

- The earth fitting are adequately connected.

- Electrical safety devices are correctly connected, duly

adjusted and ready to use.

- The wire and electrical connections inputs are

correctly sealed and water-tight.

When starting up the apparatus: 

- During the operating period the heater battery must

never be touched.

- If any electrical devices blow, the apparatus must be

quickly disconnected from main supply. The whole

installation should be carefully checked before trying

to start up the apparatus again.

- Check electricity consumption

Maintenance. 

- Before manipulating the heater battery, make sure

that it is disconnected from the main supply. Prevent

the possibility of anyone else connecting it while it is

being manipulated.

- The apparatus must be regularly inspected. These

inspections should be carried out bearing in mind the

machine’s working conditions, in order to avoid dirt or

dust accumulating.

- All maintenance and repair work should be carried out

in strict compliance with each country’s current sa

fety

regulations.

Recycling. 

EEC Standards, together with the responsibility we 

should assume with future generations in mind, oblige us 

to recycle all the materials we can. Therefore please 

deposit all left-over material and packaging in their

corresponding recycling containers and hand in the 

replaced machines to the nearest handler of this type of 

waste product. 

If you have any queries about S&P products, please 

contact our After-Sales Service Network if you are in 

Spain or your local S&P dealer in any other country. If in 

doubt, please visit our Web-page

www.solerpalau.com

MBE-R electric heating battery 

Technical data: 

The electric batteries MBE-R comply with EC Standards 

The electric batteries MBE-R incorporate 2 thermal 

protectors fitted as standard: one for automatic reset at 

60ºC and another one at 120 ºC with manual reset. 

Supply voltage:    

Single-phase: 1/230V AC, 50Hz 

Three-phase:  2/400V or 3/400V AC, 50Hz 

Protection rating: IP43 

Maximum outlet temperature: 40ºC 

Maximum ambient temperature: 35ºC 

Minimum air velocity: 1.5 m/s 

Index for wiring diagram 

REF

DESCRIPTION

1

General ON/OFF switch (heater and fan)

2

Post-ventilation timer

3

Heater relay

4

Fan relay

5

The electrical installation must include a 

double pole switch with a contact clearance of 

at least 3mm

6

Safety overheat automatic thermostat

7

Safety overheat manual reset thermostat

8

Jumper to select internal or external 

temperature setting

8a

Internal temperature setting 

with jumper

8b

External temperature setting 

without jumper

9

LED 

10

Maximum temperature setting

11

Minimum temperature setting

12

Air volume controller 

pressure switch

13

External temperature controller with output 0-

10V

14

External temperature set-point with output 0-

10V

PCB-1

Main temperature sensor connection

PCB-2

PCB-3

External temperature set point connection

PCB-4

PCB-5

Not used

PCB-6

PCB-7

Limit temperature sensor connection 

PCB-8

PCB-9

External temperature controller connection 

with output 0-10V

PCB-10

PCB-11

Pressure switch connection. If not, put a

bridge.

PCB-12

FIG.A

Supply air temperature control with sensor 

TGK 330 in duct and temperature set point 

adjusted with heater potentiometer

FIG.B

Supply air temperature control with sensor  

TGK 330 in duct and temperature set point 

adjusted with external potentiometer type TBI

30

FIG.C

Room temperature control with sensor  TGR 

530, temperature set point adjusted with 

heater potentiometer and supply air limitation 

with TGK 330 sensor in duct

FIG.D

Room temperature control with sensor  TGR 

430, temperature set point adjusted with 

sensor potentiometer and supply air limitation 

with TGK 330 sensor in duct

FIG.E

External heating control with output 0-10V. 

Heating power varies from 0 to 100% when 

output varies from 2V to 9,5V.

FIG.F

Extension of the wiring diagrams Fig. A and C,

using an external temperature set point with 

output 0-10V.

Summary of Contents for MBE-R

Page 1: ...MBE R...

Page 2: ...MBE R 90 45 0 45 0...

Page 3: ...V 50Hz KM10 Q1 L N MBE R 1 230V 50 60Hz 1 2 3 4 60 C 120 C L2 N PE 2 400V 50Hz KM10 Q1 L1 L2 MBE R 2 400V 50 60Hz 1 2 3 4 L1 24 or 230Vac 50Hz KM10 KM1 24 or 230Vac 50Hz KM10 KM1 MBE R MBE R 1 2 4 3 5...

Page 4: ...3 400V 50 60Hz 1 2 3 4 L2 L1 KM10 Q1 L1 20 25 30 35 40 45 50 0 5 10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX INT EXT MBE R PCB MBE R 2 1 4 3 5 6 7 PCB 12 PCB 11 PCB 10 PCB 9 PCB 8 PCB...

Page 5: ...10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX P 20 25 30 35 40 45 50 0 5 10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX P 1 2 3 INT EXT INT EXT 12 MBE R TGK 330 MBE R TGK 330...

Page 6: ...25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX P 1 2 20 25 30 35 40 45 50 0 5 10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX P 1 2 3 4 INT EXT INT EXT 12 12 MBE R TGK 330 MBE R TGK 330...

Page 7: ...12 21 22 23 MIN MAX P 20 25 30 35 40 45 50 0 5 10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX INT EXT INT EXT 12 8 8 FIG E FIG F 0 1 2 3 4 5 6 7 8 9 10 0 25 25 50 75 100 Pout Ureg V U reg...

Page 8: ...existe un riesgo de incendio Se recomienda instalar un filtro de aire para evitarlo Respectar una distancia m nima entre el filtro y la bater a de dos veces el di metro No utilizar estas bater as en...

Page 9: ...polar con distancia entre contactos de al menos 3 mm 6 Rearme autom tico 7 Rearme manual 8 Ajuste interno o externo de la consigna de temperatura 8a Ajuste interno puente posicionado 8b Ajuste externo...

Page 10: ...ned for indoor installation The maximum air temperature at the outlet must not be over than 40 C Fit the battery respecting the airflow direction indicated by the arrow located on the battery Use the...

Page 11: ...OFF switch heater and fan 2 Post ventilation timer 3 Heater relay 4 Fan relay 5 The electrical installation must include a double pole switch with a contact clearance of at least 3mm 6 Safety overheat...

Page 12: ...ent des r sistances lectriques augmente le risque d incendie L utilisation d un filtre air en amont de la batterie est recommand e Respecter une distance minimale de deux fois le diam tre entre le fil...

Page 13: ...e des contacts sup rieure 3 mm 6 R armement automatique 7 R armement manuel 8 R glage interne ou externe de la consigne de temp rature 8a R glage interne pontage en position 8b R glage externe pas de...

Page 14: ...batteria in atmosfere esplosive o corrosive La temperatura massima dell aria ambiente non deve su perare i 35 C Non installare le batterie in una parte della rete del con dotto in cui possa prodursi...

Page 15: ...ione interna o esterna del setpoint della temperatura 8a Correzione interna Ponte posizionato 8b Correzione esterna Senza ponte 9 LED di funzionamento della batteria 10 Correzione del limite inferiore...

Page 16: ...Ref XXX S P SISTEMAS DE VENTILACI N S L U C Llevant 4 Pol gono Industrial Llevant 08150 Parets del Vall s Barcelona Espa a Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com...

Reviews: