SILENT-100 CRIZ

SILENT-100 CHZ

SILENT-100 CDZ

This model is provided with an adjustable
over-run timer. The timer allows the fan to
continue to operate for the selected period
after the switch has been turned off (fig.6).

Model provided with a 4 positions adjustable
electronic timer:Fig.5 shows how to connect
the fan with timer utilising the same switch as
for the lighting circuit.
To set the timer, turn the potentiometer on the
printed circuit board as (fig. 7).

:

If the period of operation is less than 50
seconds then the over-run timer will not
operate
If the period of operation is more than 50
seconds then the over-run timer will operate
in accordance to the period of operation
(period of operation x 2 with a maximum of
30 minutes).

: 5 minutes "run on" time

: 20 minutes "run on" time
: 30 minutes "run on" time

Models provided with an electronic
humidistat which can be adjusted from 60%
to 90 % RH (relative humidity) and with a
timer, adjustable between 2 and 20 minutes.

Operation

1: Automatic operation (fig.9)

In automatic operation, the humidistat
causes the extractor to operate automatically
when the humidity level in the room is higher
than the set level. The extractor will stop
automatically when the humidity drops below
the selected level and after the selected
period set on the timer.

2: Automatic operation as in case 1

with the facility to override the hygrostat by

means of the light switch (fig.8), when the
humidity level in the room is lower than the
selected level.

In this case, the extractor

continues to operate for the selected period
set on the timer after the switch light has
been switched off.

The desired humidity level is selected by
means of a potentiometer “

” positioned

on the printed circuit board (fig.10) and
accessible once the grille (1) has been
removed.
- To increase the humidity setting turn

anticlockwise (min.60 %)

- To reduce the humidity setting turn

clockwise (max. 90 %)

To set the timer, turn the potentiometer “

” on the printed circuit board (fig.10):

- To reduce the "run on" time,

turn

anticlockwise (min. 2 minutes)

- To increase the "run on" time , turn

clockwise (max: 20 minutes).

Models provided with a PIR (passive
infra-red)

detector. The

unit

starts

automatically

when

a

movement

is

detected with a maximum distance of 4
metres (fig.9).
They are also fitted with an adjustable
"run on" timer (1 to 30 minutes), and the
unit will continue to operate for the set
period after initiation by the movement
detector.

To set the temporisation, turn the
potentiometer on the printed board (fig.7):
- To reduce the "run on" time,

turn

anticlockwise (min. 1 minute)
- To increase the "run on" time,

turn

clockwise (max: 30 minutes).

ATTENTION: The product also includes
an over-run timer facility that starts the
fan after the first 50 seconds of non-
operation. After these first 50 seconds the
fan operates automatically.

Case

Case

ATENTION: When the himidity rate is
above the selected value, the automatic
option takes precedence over the manual
and the unit cannot then be switched off
using a switch.

% Hr

t

min.

Position Auto

Position 5'
Position 20'
Position 30'