background image

Mounting instructions
In-line axial fans

The TDM-200 has been manufactured in accordance to the rigorous standards of production 
and quality as laid down by the international Quality Standards ISO 9001. All the components 
have been checked and all the fi nal products have been tested at the end of the manufacturing 
process.
This appliance is not intended for use by young children or infi rm persons unless they 
have been adequately supervised by a responsible person to ensure that they can use the 
appliance safely. 
Young children should be supervised to ensure that they do not play with the appliance. 
Check that the appliance is in perfect conditions when unpacking, as any manufacturing 
fault is covered by the S&P guarantee.
The installation procedure must be done in accordance to the electrical standards in force 
in your country.

Installation

–  The TDM-200 has been designed to be either buit-in or duct mounted. In both cases, the 

hole or the duct diameter must be 120 mm.

–  Once installed, check that the propeller turns freely.
–  Connect the electrical wire to the terminal box, feeding it through the cable fi xing 

clamp.

Electrical connection

–  The TDM-200 is a class II unit (double insulation) and does not need earth connection.
–  The fan can be controlled by an independent switch or by a light switch. It can also be 

started by an higrostat or an air quality sensor.

–  The electrical installation must incorporate a single pole switch with an air gap of at least 

3 mm.

–  In bathrooms, the unit must be installed in such a way that it is out of the reach of a person 

who is under the shower or the bath. The switch must either ceiling pull cord operated or 
installed outside the bathroom.

–  Precautions must be taken to avoid the back-fl ow of gases into the room from the open 

fl ue of gas or other fuel-burning appliances. 

Technical features

– Maximum 

airfl ow: 200 m

3

/h

Reviews: