12
3.- OPERATING MODES (Fig. 10)
Extraction mode
Using the buttons
/
+
you can select up to 4 speeds. On the screen is displayed speed
selected.
Speed 1
LOW
Speed 2
MEDIUM
Speed 3
HIGH
Speed 4
BOOST (timed)
Keeping
button pressed for 2 seconds the hood turns off.
Boost mode
The hood incorporates a working mode called BOOST. It is the highest speed timed useful
when maximum performance is required.
This mode is selected by keeping p button until the screen shows Speed 4. After 15
minutes, the speed is reduced one level (speed 3) automatically.
Run-on-timer
Using the botton
you can activate a run-on-timer that will keep selected speed for 10
minutes before the hood turns off automatically.
Air recirculation mode
Being the hood stopped and keeping the button
pressed for 2 seconds, air recirculation
mode will be activated.
On the screen appears
. The hood will start up in speed 1 (LOW) for 10 minutes. Then, it
will remain stopped for 50 minutes showing a letter C on the screen.
This cycle (10 minutes ON / 50 minutes OFF) will continue indefinitely until user desire.
This mode is disabled when button
is pressed.
4.- MAINTENANCE
IMPORTANT!
Before carrying out any cleaning or maintenance operation, disconnect the hood
from the electricity supply.
Satisfactory operation of the hood depends on the frequency with which maintenance
operations are carried out and especially frequency with which the greaseproof active carbon
filters are changed.
The metal filters are used to trap the grease particles that are suspended in the air, which can
obstruct the filters over time, depending on how often the device is used. In any event, to avoid
fire hazards, the filters should be cleaned at least every two months according to the following
instructions:
.- Remove the filters
(Fig.4)
from the hood and wash them with a solution of water and
neutral liquid detergent and leave the dirt to soften.