IMPORTANT TIP: Insulate the network with a layer of glass wool (70 mm) to improve network insulation and
insulate the dual flow unit similarly.
4. SETTING THE VENTILATION
4.1 Kitchen flow control
The kitchen vent is connected to the Ø125mm nozzle of the
extraction plate.
Type of housing
Setting the kitchen flap lever
T2/3
T4
T5 y +
Position 3
Position 4
Position 5/+
4.2 Adjustment of other wet rooms
Wet room vents are connected to the Ø80 mm nozzles on the face extraction
According to the housing regulations, flows are:
T3 to T7 housing
Regulator set at 15 m
3
/h
Regulator set at 30 m
3
/h
Room(s) with bath or shower
30 m³/h
Single WC
30 m³/h
Multiple WC
15 m³/h
Other wet rooms: laundry…
15 m³/h
Fresh air output
Plenum
4 nozzles
Air output nozzles
Air output nozzles
Plenum
8 nozzles
Exhaust air
Fresh air
Exhaust Plenum
5 nozzles
i l d d
Extraction nozzles
OR
OR
Air outlet
Air intake
Exchanger